Connection of alarm contacts, auxiliary contact and VCR Trigger
The connection of alarm contacts, auxiliary contact and VCR Trigger must be carried out on the
ALARM
15-pole
connector, placed at the rear of the mechanics.
Connection of alarm contacts
The sequential switcher allows each video input to be associated with an alarm contact.
Where to operate
: Pin 1..9 of
ALARM
connector
Settings
: connect each alarm contact between Pin 9 (Alarm common) and a Pin from 1 to 8 corresponding to the input
desired.
Pin Connection to perform
1
Alarm 1 Input
2
Alarm 2 Input
3
Alarm 3 Input
4
Alarm 4 Input
5
Alarm 5 Input
6
Alarm 6 Input
7
Alarm 7 Input
8
Alarm 8 Input
9
Gnd (alarm common)
WARNING!
Do not energize the alarm contacts
.
Connection of the auxiliary contact
The sequential switcher allows the control of an auxiliary contact which is activated in case of alarm.
Where to operate :
Pin 12, 13 of
ALARM
connector
Settings
:
•
Normally open contacts (NO) : connect between Pin 12 (Relay common) and Pin 13
Pin Connection to perform
12
Relay common contact
13
NO relay contact
Connection of VCR Trigger
Pin 10 of
ALARM
connector functions as input for
TTL
or
open collector
signals. It is possible to connect to this
Pin the Trigger signal from VCR or alternatively a signal for the sequential switcher external reset. Trigger or reset
signal is seen on the descent front.
Where to operate
: Pin 10 of
ALARM
connector - Pin 9 Gnd (ground)
Settings
: connect the VCR Trigger signal to Pin 10 of
ALARM
connector
Connection of External Reset signal for the sequential switcher
Where to operate
: Pin 11 of
ALARM
connector -
Pin 9 Gnd (ground)
Settings
: connect the External Reset signal to Pin 11 of
ALARM
connector