Pag. 11
SM42A / SM82A 2802
Connect the telephone cables as in the following diagram:
Connecting RS 485 KEYBOARD lines
MATRIX
RJ-jack 1
RJ-jack 2
KEYBOARD
RS485-A
Blue
-----------------
White
RS485-A
RS485-B
Black
-----------------
Yellow
RS485-B
12 VDC
(1)
Red
-----------------
Green
12 VDC
GND
(1)
Green
-----------------
Red
GND
(1) powering the keyboards from the matrix is only possible with the DCTEL and DCBD keyboards and with
the LXRPK12 and LXRPK23 Linxs series keyboards and in any case, up to a maximum distance of 700m
3.5.4.2
Telemetry receivers (AUX line)
All the receivers specified in section 2.2
Connectable devices and the SM42A / SM82A video matrix can be
connected by telephone cable using the RJ-11 socket called AUX.
They can be connected directly using the 1.5m cable (supplied by the manufacturer) for a test or, for longer
distances, using the RJ-jack wall-mounted boxes (supplied by the manufacturer) and referring to the following
table:
RS 485 matrix (AUX line) – Receiver connection
MATRIX
RJ-jack 1
RJ-jack 2
RECEIVER
RS485-A
White
-----------------
Blue
RS485-A
RS485-B
Yellow
-----------------
Black
RS485-B
All the receivers should be set up for RS485 communication mode and with a transmission rate that is compatible
with the setting made for the matrix at the programming stage.
See the respective manuals for configuring the receivers.
There are two possible ways of connecting the receivers to the AUX line:
•
Receivers in cascade (Point-to-point connection)
•
Receivers on the same line (Multi-point connection)