Instruc
tion manual - English - EN
3
MNVKMPX2C_2225_EN
5.3 Safely disposing of packaging
material
The packaging material can all be recycled. The
installer technician will be responsible for separating
the material for disposal, and in any case for
compliance with the legislation in force where the
device is to be used.
6 Installation
Make all connections, installation and
maintenance work in a non-explosive
atmosphere.
Electrical connections must be performed
with the power supply disconnected and
the circuit-breaker open.
Never, under any circumstances, make
any changes or connections that are not
shown in this handbook. Failure to follow
the connection instructions that are given
in the handbook may create serious safety
hazards for people and for the installation.
Do not change the wiring in the product
as it is supplied to you. Failure to follow
this instruction may create serious safety
hazards for people and for the installation,
and will also invalidate the warranty.
Keep the connection diagram for future
reference.
6.1 Multipolar cable connection
To avoid damaging the cables, insert them
one at a time using the cable input.
Consult the product manual for all the
operations for opening and closure of the
connections compartment and the cable
inputs.
Remove the cable input safety plug on the left (01).
Loosen the connection compartment cap (02).
01
02
Fig.
1
To facilitate assembly, loosen the cable gland
following the instructions provided in the
manufacturer's manual.
Pass the conductors through the cable input with
the respective connectors. Insert in order:
• the cable bundle with the six-pole connector
(which should be slightly tilted);
• the bundle with the five-pole connector;
• the power supply cables;
• the Ethernet cable.
The cables must not be twisted during
cable gland tightening.
To maintain the product degree of IP,
apply sealant to the threads, in compliance
with IEC/EN60079-14.
Re-assemble the cable gland, fixing it to the
product, following the instructions provided in the
manufacturer's manual.
Connect the Ethernet cable, the signal and power
supply cables to the boards in the connections
compartment.
Consult the use and installation manual of
the product for further information.
Close the connections compartment.
Содержание MPX2CABL
Страница 2: ......
Страница 36: ...RU 2 MNVKMPX2C_2225_RU 4 2 2 4 4 1 IP66 IP66 PTZ MAXIMUS MPX SERIES2 4 2 5 5 1 5 2...
Страница 37: ...RU 3 MNVKMPX2C_2225_RU 5 3 6 6 1 01 02 01 02 1 Ethernet IP IEC EN60079 14 Ethernet...
Страница 38: ...RU 4 MNVKMPX2C_2225_RU 6 2 01 02 01 02 2 IP IEC EN60079 14 Ethernet...
Страница 52: ...KO 2 MNVKMPX2C_2225_KO 4 2 2 4 4 1 MAXIMUS MPX SERIES2 PTZ IP66 IP66 4 2 5 5 1 5 2...
Страница 53: ...KO 3 MNVKMPX2C_2225_KO 5 3 6 6 1 01 02 01 02 1 6 5 IP IEC EN60079 14...
Страница 54: ...KO 4 MNVKMPX2C_2225_KO 6 2 01 02 01 02 2 IP IEC EN60079 14...
Страница 59: ......