Vi-Q4/C3
User Manual
Viq602c
Command
Name
Command
Originator
CC
PP
Description
0x01
Menu Mode
VP
0x44 0xEA VP reports the menu mode. A single extended data byte XX
identifies the menu off (normal operation) as 0x00 or Menu
active as 0x01
MENU
EXT
0x01 0x00
Enter menu mode
Up
EXT
0x04 0x00
Navigate up
Down
EXT
0x05 0x00
Navigate down
Left
EXT
0x06 0x00
Navigate left
Right
EXT
0x07 0x00
Navigate right
Escape
EXT
0x03 0x00
Back one menu level
Default
EXT
0x0E 0x00
Default menu setting
Live
EXT
0x34 0x00
Exit menu
Function
EXT
0x64 0x00
Test function. Follow by one or more numbers 1-9, then an
OK command
OK
EXT
0x02 0x00
OK comand
ASCII
EXT
0x63 0x00
to
0xFF
Send ASCII character, eg 0x30 to 0x39 for numbers 0 to 9
Baud
EXT
0x9D Rate/
1200
Set baud rate. Parameter CC is required baud rate divided by
1200. e.g. for 9600 CC would be 0x08
Upgrade
EXT
0x54
Enter upgrade mode. Extended data XX.XX must encode this
ASCII string: Vi-Q4C3
Parse record
EXT
0x48
Extended data XX.XX block. Repeat until entire program
image has been sent
Flash
EXT
0x49 0x00
to 0xff
Start flash process if CC maches checksum of downloaded
firmware image data
Cancel
upgrade
EXT
0x7A 0x00
Cancel flash program mode