http://www.videopark.com.cn
Email:
26
3.6.3. ALARM OUTPUT
Alarm output is relay output, please refer to the relay parameters to avoid overload and damage the host.
Explain:
Contact Material
Silver
Electric property
Maximum switching power
240VA,48W
Maximum switching voltage
125VAC,60VDC
Maximum
2A
Form 3- 18
3.6.4. P/T/Z CONNECTION
A, B ports of RS-485 link with A, B ports of PTZ decoder. A is the RS-485+ terminal, B is the RS-485 – terminal. Parallel
connect 120
Ω
resistances at A, B ports to reduce signal reflex if there are several PTZ decoders.
3.6.5.
Step 1.Con
Step 2.Con
DC 4
Step 3.POE power supply network interface, Internet cable is connected, Internet cable at the other end is connected to
the front end of a webcam (camera support POE power supply). POE power supply theoretical distance not more than
100 meters.
3.7. MOUSE
In addition to front panel keys and remote control menu, the user can use mouse for menu functions. Insert mouse with
USB interface into machine panel.
Click Left Button
If the user does not log in, password box will pop up first; click the left mouse button to enter the main menu when
real-time monitoring.
Left click mouse the Options icon enter the menu.
Exact Instructions on control
Change the state of check box and dynamic detection block.