www.videofied.com

I N S T A L L A T I O N   M A N U A L

18

3. XLL Features Guide

Unscrew the locking screw on the left-hand side of the panel, using a paper clip push through the opening hole to open the 
panel’s cover.

When user disarms the system, the keypad 
indicates the last event. 

In case of the user needs to read the full log 
file, use the keypad to go in EVENT LOG, 
press  

OK or YES

 on SELECT LAST EVENTS 

and use arrow to list the events.

3.6 Read the event log

3.7 Opening the cover of an installed panel

3.8 Golden Rules

Press 

OK or YES 

for more information about an event

EVENT

LOG

SELECT LAST 

EVENTS

OK 

or 

YES

 15/10/13 

11:29

MODIFIED PARAMET

OK 

or 

YES

 15/10/13 

11:10

SYSTEM DISARMED

1

   Area 1 is always 

delayed. 

When you register a keypad or a badge  

 

reader into an area, that area will automatically be delayed.

 

2

 

Never position

 a panel next to 

a high voltage electrical cabinet

 .

3

  Press CLR to erase a typing mistake.

4

  Never register the same device twice (delete from the system first).

5

  Registration of  

up to 25 devices

 (including the keypad).

6

  Respect indoor infrared devices installation height (

2m10 to 2m30)

.

7

  Outdoor cameras have to be installed at 

2m60 to 3 meters   

 height

. Those devices need to to protect an access and not a zone.

8

  Do not fix the keypad at the beginning of the installation as it will  

 

need to be portable during programming.

 

Always clean 

the lens of the cameras after the installation    

 

(Use a clean, dry cloth, taking care not to exert pressure on    

 

the lens).

9

10

  To switch between UPPER and lower case, use the M/m  

 

 

key from the CMA keypad or hold a digit key (0 to 9) for  

 

 XMA/XMB.

11

  Internal components are fragile, be careful opening or  

 

 

closing the panel.

 

LCD screen goes dark after 30 seconds of inactivity, press an  

 

arrow or numeric key to light it up.

13

  Use only batteries provided by RSI (siren : Alkaline    

 

 batteries). 

14

  Infrared detectors should never be installed in stairs or close    

 

to stairs (false alarm risks).

15

  A colon display [:] means that the parameter can be  

 

 changed.

12

Содержание XL200L

Страница 1: ...XL200L XL600L XL700L GPRS Control Panel I N S T A L L A T I O N M A N U A L www videofied com Doc Ref 230 XLL Last modification date June 2014 Firmware version XLP 04 04 05 XXX and later ...

Страница 2: ...ted Wireless technology providing optimum signal integrity and security The bi directional RF communication path between all devices and the system control panel guarantees high signal reliability Integrated antennas eliminate protruding wires or rods both more difficult to install and unsightly to consumers and potentially troublesome if damaged The panel supervises every device excluding the rem...

Страница 3: ...pad 5 2 XLL Panel Programming 6 3 XLL Features Guide 13 3 1 Get to Access level 4 13 3 2 How to Arm Disarm the System 13 3 3 Arming and Siren Mode Configuration 14 3 4 Manage badges and access codes 15 3 5 Delete the keypad or any other device 17 3 6 Read the events log 18 3 7 Opening the cover of an installed panel 18 3 8 Golden rules 18 4 Transmitted Events List 19 5 2G3G Error Codes 20 6 Techni...

Страница 4: ...eAlkalineDtypebatteriesasshown ensuringthepolaritymatchesthelabelingonthe insideofthebatterycover Bracket holes Before removing the front cover from its box Put the SIM card on the plastic base Take care to respect the right direction DO NOT insert or remove the SIM card while the panelispowered 1 2 SIM Card Installation 1 3 XLL Assembly Connect the panel s face to its base by carefully placingthe...

Страница 5: ...r LED blinks twice The panel is now reset a CMA XMA or XMB has to be enrolled to configure the panel THE CONTROL PANEL MUST BE CONNECTED TO AN EXTERNAL POWER SUPPLY OPTION 1 WHEN USING THE RINGTONE FEATURE OR SMARTPHONE APP Batteriescable Batteriesconnector MainsConnector Programmingbutton Option 1 Option 2 To install the power supply inside the box break the plastic battery separator www videofie...

Страница 6: ... XX or Press on both CLR and ESC NO keys at the same time and release The indicator LED on the keypad will blink rapidly Wait for the keypad to pair If the keypad doesn t pair up with the panel and shows XX it certainly means that it is still paired to another system and needs to be reset Take the batteries out and press repeatedly on the keypad tamper switch Then proceed to the above steps www vi...

Страница 7: ...he control panel The keypad will display a real time radio range value on a scale of 9 To receive the most accurate results you must run the radio range test for at least 30 seconds Result must be 8 out of 9 or better for reliable transmission Using the Alphanumeric Keypad enter the Installer Code of your choice The Installer Code will be used for all future maintenance and configuration This code...

Страница 8: ...me blank by pressing ESC NO it will be named ACCESS 1 by default Please wait ADJUSTING DATE AND TIME DATE YEAR 12 To set the year OK orYES DATE MONTH 13 01 To set the month OK orYES You may proceed in the same way for Day Hour and Minutes 13 10 14 10 47 ENTRY COMPLETE ACCOUNT NUMBER CONNECTED TO MONITOR STATION OK orYES Use the Alphanumeric Keypad to enter in a 4 8 digit account number provided by...

Страница 9: ...configure the transmitted events to the monitoring station use the arrow keys to toggle between events and OK or YES to modify ALARM event transmitted upon occurrence ALARM END event is transmitted on occurrence and on event restoral NOT TRANSMITTED event is not transmitted however it will appear on the keypad Please liaise with your Monitoring Station to ensure that the requested events to transm...

Страница 10: ...caseletters To switch between UPPER and lower case use the M m key from CMA keypad or hold a digit key 0 9 for XMA XMB ESC NO ESC NO The IP1 address Domain name 1 and or Port 1 are provided by the monitoring station Leave Port details at 888 unless otherwise instructed Press OK orYES to enter modify the parameter then OK orYESfor validation WARNING You will use either an IP adress or a Domain name...

Страница 11: ...ATIBILITY EN 50131 NORMS For full compatibility with EN50131 press OK orYES Otherwise press ESC NO ESC NO AREAS CONFIGURATION AREA 1 NAME Press ESC NO to default the area names Enter the name of the area 1 and OK orYES Repeat the procedure for areas 2 3 and 4 For further details please refer to chapter 3 3 ENTRY DELAY 15 sec EXIT DELAY 45 sec For the selection OK orYES For the selection OK orYES O...

Страница 12: ...disarmed until a user code or badge is entered the installer code cannot arm or disarm the system Press OK or YES to register one or more badges ESC NO if you re not using any badges If you wish to use an user code please skip this step and once the system configuration done go to the BADGES ACCESS CODES menu please refer to chapter 3 4 for further details Badges and codes are limited to 19 for us...

Страница 13: ... your user code With remote badge reader BR250 N A Present your badge on the badge reader N A N A With remote keyfob N A N A Press Press www videofied com I N S T A L L A T I O N M A N U A L 13 3 1 Get to Access level 4 Tue 29 10 11 23 DISARMED LVL 1 ACCESS LEVEL 1 ACCESS LEVEL LEVEL 1 ACCESS LEVEL LEVEL 4 OK orYES OK orYES To unlock and get access to the installer level 4 you need to successively...

Страница 14: ...o the menu CONFIGURATION LVL 4 AREAS AND DEVICES DEVICES DEVICES CONFIGURATION DEVICE TYPE Siren Immediate triggering of all sirens Delay Beeps Entry Exit delay beeps then triggering of all sirens Silent No Sirens No Beeps Without Siren Beeps on the keypad only Use to go to menu CONFIGURATION LEVEL 4 SPECIAL ARMING MODES FULL ARM SP1 or SP2 Use direction arrows to select the arming mode you want t...

Страница 15: ...vent log test the devices Modifications of the settings are not possible at this level User Level 3 can create Level 2 or Level 3 access codes or badges LVL 4 INSTALLER level where it is possible to modify the setup of the panel To access Level 4 the approval of a Level 3 oe Level 2 user is required Installer Level 4 can creat the first Level 3 access code only How to return to the LVL1 After 1 mi...

Страница 16: ...ACCESS CODES ENTER A BADGE CODE Enter a 4 6 digit user code and OK orYES or present a badge in front of the reader until you hear the registration beep OK orYES OK orYES OK orYES OK orYES OK orYES OK orYES The XLL system can accept up to 19 1 installer code Badges or Access codes in any combination The table presents the reserved code possibilities that cannot be used A total of 186 codes are forb...

Страница 17: ...L Features Guide Youcannowremovethebatteriesfromthedevice ACCESS LEVEL 4 CONFIGURATION GENERAL PARAMETERS OK orYES to select the device and press OK orYES XX DELETE AREAS AND DEVICES DEVICES ADD A NEW DEVICE DEVICE CONFIGURATION A1 KEYPAD KEYPAD 1 OK orYES OK orYES OK orYES Devices list OK orYES OK orYES ...

Страница 18: ... Press CLR to erase a typing mistake 4 Never register the same device twice delete from the system first 5 Registration of up to 25 devices including the keypad 6 Respectindoorinfrareddevicesinstallationheight 2m10to2m30 7 Outdoor cameras have to be installed at 2m60 to 3 meters height Those devices need to to protect an access and not a zone 8 Do not fix the keypad at the beginning of the install...

Страница 19: ...u CODE STATE MODIFICATION Use the arrows to access CONFIGURATION level4 CONFIGURATIONMONITOR STATION MONITORINGPARAMETERS EVENTTRANS MODIFICATION Then use the arrows to determine the event to modify Press OK orYES to edit These are the default transmitted events DEVICE intrusions ALERT Panic Buttons PANEL LOW BATT TAMPER DEVICE LOW BATT PERIODIC TEST DURESS CODE FIRE MEDICAL ASSIST ETHERNET CABLE ...

Страница 20: ...ents or codes are subject to change by SIM card operators However the GPRS level test errors results in the majority of cases have the following causes SIM Card activation Delay Some operators require an additional delay up to 48 hours to activate automatic data transmission Please check with your operator prior to installation APN CODE USERNAME and PASSWORD The GPRS 2G3G settings are supplied by ...

Страница 21: ...5 A1 2009 Grade 2 EN50131 6 2008 Grade 2 Type C EN50130 4 1995 A1 1998 A2 2003 EN50130 5 1998 Class II Siren 15 min maximum duration Indoor use only Can be self powered 105 dB A at 1 meter Notes de sécurité EN Security notes DE Hinweise zur Sicherheit Français Retirez les piles avant toute opération de maintenance Attention Il y a un risque d explosion si l une des piles utilisées est remplacée pa...

Отзывы: