background image

The WIO100 programmable output is a dry contact 
triggering a wired external device. These outputs 
can only be wired to SELV circuits. 

The woltage and 

current are limited to 24V/100mA

.

Programmable outputs OUT 1 and OUT 2 can be 
triggered by : 

•  An event linked to the panel or its devices. 
•  The triggering of the programmable input or the 

arming input. 

OUT 1 programmable output connection

2.  Programmable outputs

2.1 Programmable outputs triggering

INTRUSION
TAMPER
PANIC BUTTON
INCORRECT CODE
DURESS CODE 1
DURESS CODE 2
SUPERVISION
RADIO JAMMING
LOW PANEL BATT.
LOW DEVICE BATT
AC POWER MISS.
PANEL RESET
SYSTEM ARMED
SYSTEM DISARMED
PERIODIC TEST
ALARM CANCEL
SMOKE DETECTION
PHONELINE MISS.
TMT REQUEST
MEDICAL ASSIST.
ETHERNET CABLE
DETECTION
PROG. INPUT 1 

You can find below the list of events that can trigger a programmable output.

6

W Panel 

www.videofied.com

WIO 100 Input/Outputs module

A P P L I C A T I O N   N O T E

Содержание WIO100

Страница 1: ...g the programmable input can be set up to take a 10 second video from any Videofied Motion Viewer when the detector linked to the programmable input is triggered The programmable input can also be wired to an existing alarm system in order to add video vérification That mode is called XTENDER mode Programmable outputs are normally open drys contacts that close when the output is activated Index 1 ...

Страница 2: ...tc You can find the event list on the next page Entry delay in seconds between the input triggering and the alarm triggering event transmission 0 3600 seconds Input Name This name can be seen by the monitoring center when the input triggers Choose a detailed name Siren type for the programmable input Siren the siren will be enabled and the keypad will beep Silent no siren no beeps Without siren on...

Страница 3: ...nked device triggering The security server will receive this event when the programmable input triggers Important These events are different from the events transmitted list in the FRONTEL SECURITY PARAMETERS menu They will be sent no matter how the events listed in the EVENT TRANS MODIFICATION are set 1 3 Programmable input wiring and supervision Programmable input wiring IN IN OUT1 OUTN OUT2 Pro...

Страница 4: ...the panel 4 W Panel www videofied com WIO 100 Input Outputs module When used in XTENDER mode arming devices keypads keyfobs badge readers cannot arm or disarm the system To switch between standalone mode and XTENDER mode go to the menu CONFIGURATION Lvl 4 GENERAL PARAMETERS XTENDER Note Enabling the programmable input will automatically disable the XTENDER mode and switch the W panel in standalone...

Страница 5: ... YES to select the parameter Enter the value for your Entry Delay up to 255 seconds and press OK or YES Note In From the Host mode the entry exit delay are managed by the master system Arming Confirmation is the number of seconds the system will wait to arm after voltage is latched on the arming input This feature can be used as an exit delay we suggest you to enter the same value as your master s...

Страница 6: ...UT 1 programmable output connection 2 Programmable outputs 2 1 Programmable outputs triggering INTRUSION TAMPER PANICBUTTON INCORRECTCODE DURESSCODE1 DURESSCODE2 SUPERVISION RADIOJAMMING LOWPANELBATT LOWDEVICEBATT ACPOWERMISS PANELRESET SYSTEMARMED SYSTEMDISARMED PERIODICTEST ALARMCANCEL SMOKEDETECTION PHONELINE MISS TMT REQUEST MEDICAL ASSIST ETHERNET CABLE DETECTION PROG INPUT1 You can find belo...

Страница 7: ...ammable output in cas of alarm EVENT TYPE INTRUSION Type of event assigned to the input intrusion smoke detection tamper assistance detection etc When the event occurs the output will activate OUTPUT NAME OUTPUT 1 Output name In order to recognize which system is connected to the output choose a detailed name 7 North American Headquarters 1375 Willow Lake Blvd Suite 103 Vadnais Heights MN 55110 US...

Отзывы: