Factory Test & Alignment Specification For MS801-AP Series (V1.0)
Page 7 of 17
in-depth test can be performed faster using suitable UART/IR commands following SIACP
requirements. SW will internally manage Network ID (NID) flag controlling all MAC Address /Device
ID/User ID integrity to facilitate PA screening further.
See Appendix
“NETWORK CONNECTION AND TEST”
2. Product Assembly (PA): Test & Alignment
2.1. Factory Menu
Follow the below steps to pop-up the Factory m
enu in case of “
FactoryKey
” is
disabled:
- Enter into TV source,
TV setting
Picture
Contrast
,
- Press the subsequence RCU
keys “
9
”, “
7
”, “
3
” and “
5
”
In case of
“
Factory Key
” is
enabled, just press RCU
“
Return
”
key to pop-up again the Factory
menu.
The status of
“
Factory Key
”
can be changed in
Factory Menu->Factory hotkey.
Press RCU
“
OK
”
key to enter the submenu.
Press RCU
“
Menu
”
or
“
Return
”
key to go back to the root menu.
Press RCU
“
Right
”
or
“
Left
” key
to change the values.
Press RCU
“
Right
”
or
“
Left
”
key run the function.
Press RCU
“
Return
”
or
“
Menu
”
key exit the Factory menu.
Factory Captions Info.
While “
Factory Key
” is enabled
, there is some toggled display information relative to
SW
,
Project ID
, ,to facilitate 100% quick screening without accessing to whatever else menu:
P
(Production/Factory mode flag) /
D
(Design mode flag)
/
PW
(Warm-Up mode flag)
SV
(Main SW Version)
MV
(Mboot SW Version)
ID
(Project ID)
See Appendix
“Factory Menu Description”
2.2. Warm-up Test
Followin
g TCL standard and practices, it’s required minimum
15min
of
Warm-Up
that can be
considered as
Burn-In
. Additional aging for
White Balance
alignment is no more necessary due to
consistent picture performance with cloning usage. This function is accessible
by selecting “
Factory
menu
Warm up
”,
pressing RCU
“
Right
”
or
”
Left
”
key to set it
ON
, and then it enter in
Warm up
mode. Other faster methods are available on above enclosed SIACP requirements (rev. v3.9).
2.3. White Balance (WB)
Содержание MS901K-AP
Страница 9: ...GOC 5 38...