Factory Test & Alignment Specification For MS801-AP Series (V1.0)
Page 5 of 17
In case of “
Design mode hotkey
” is
enabled, press
“
Return
”
to enter
Main Menu
. To modify
Project ID, you need to go through
“
Service menu
Project ID
”,
then press
Left
or
Right
key to
select suitable ID (Project name is dynamically refreshed).
See Appendix
“How to change Project ID with RCU”
Here below is none exhaustive ProjectID table for reference:
MODEL
ProjectID
Panel Name
TCL No.
Clientype
L49E5700UDS
124
MT4851D01-1
4A-LD49E5-CS1STA
1.4. Functional Test
Once the boards (chassis, KB, IR, PSU
…)
and the panel are well interconnected, plug all
external generator devices to relevant inputs/outputs below according to their respective test patterns
format and check picture content and sound quality accordingly:
Source
Test Signal
Test Pattern
Analog Tuner
(VHF/UHF)
RF cable generator
1. Frequency Range: full band
2. Standard: PAL DK/BG/I
、
NTSC M
、
SECAM DK/BG
SPDIF
(copatial)
Suitable signal
--
AV1
via mini jack adaptor
(CVBS&Audio)
Chroma/Fluke
generator
PAL Half Color & Gray bars
AV2
(CVBS&Audio)
Chroma/Fluke
generator
PAL Half Color & Gray bars
VGA
(VGA&Audio)
Chroma/QuantumData
generator
1024x768@60Hz
Half Color & Gray bars
CMP
(YPrPb & Audio)
Chroma/QuantumData
generator
1080i@60Hz
Half Color & Gray bars
HDMI
(Video & Audio)
DVD with HDMI
compliancy
Movie 720p@60Hz
LAN
(RJ45)
Ethernet
Any network
AV OUT
via mini jack adaptor
(Video & Audio)
RF signal
Suitable channel
Audio tones can be defined by the factory (ie: 1KHz & 3KHz, sweep, …).
Picture video formats can be changed by the factory according to their own standard.
See Appendix
“3D Format Availability vs Source Matrix”
1.5. AD Calibration Test
Содержание MS901K-AP