IP Digital H.264 Video Encoder Series Manual Rev. B
5
Connectors, I/O & Slots:
Device Hard Reset:
Each IP Video Encoder includes a convenient Reset button which is used to restore the factory default settings.
Disconnect the Power Adapter from the
“DC 12V”
input plug to power
OFF
the device.
Press
and
HOLD
the reset button by inserting the supplied paper clip into the
“RST”
terminal while
simultaneously reconnecting the power adapter.
Continue to HOLD
the
“RST”
button for 15-20 seconds until the red
“STATE”
LED becomes solid.
To confirm a successful Hard Reset, access the Encoder through a standard internet browser using the
Default IP Address, Login (888888), and Password (888888). Repeat these steps should you be unable to
access the IP device.
Device Default Parameters:
IP Encoder Parameter
Default
IP Address
192.168.1.19
Subnet Mask
255.255.255.0
Gateway
192.168.1.1
Data Transfer Port
3000
Data Control Port
3001
Remote Reply Port
3002
Web Port
80
Multicast Address
235.1.1.1
Multicast Port
6500
Remote Host Port
3004
Alarm Host Port
9000
DNS Server Port
8080
Login and Password Parameter
Default
Admin User Name
888888
Admin User Pwd
888888
Common User 1 Name
1
Common User Pwd
1
Common User Name 2
2
Common User Pwd
2