Appendix:
1.
Loads which can be controlled directly
by the Load Disconnect output of the BMS
Inverters:
All Phoenix inverters VE.Direct
Connect to the
left
hand terminal of the 2 pole connector
Phoenix 12/800; 24/800; 48/800
Phoenix 12/1200; 24/1200; 48/1200
Connect to the right hand terminal of the 2 pole connector
DC
-
DC converters:
All Tr type DC-DC converters with remote on/off connector,
and Orion 12/24-20; 24/12-25; 24/12-40; 24/12-70
Connect to terminal H of the 2 pole connector
BatteryProtect
and Smart BatteryProtect
Connect to the right hand terminal respectively to terminal H
of the 2 pole connector
Cyrix
-
Li
-Load
Connect to the control input
2. Loads for which an inverting remote on
-
off cable is needed
(article number ASS030550100)
Phoenix 12/180; 24/180; 12/.250; 24/350
All Phoenix VE.Bus inverters rated at 3kVA and more (see fig 4)
3.
Solar charge controllers which can be controlled directly by the Charge Disconnect output
BlueSolar MPPT 150/70 and 150/80 CAN-bus
Connect to the
left
hand terminal of the 2 pole connector (B+)
SmartSolar MPPT 150/45 and higher, Smart Solar MPPT 250/60 and higher
Connect to the right hand terminal ( or H) of the 2 pole connector
4. Solar charge controllers
for which a VE.Direct
non inverting remote on
-
off cable is needed
(article number ASS030550310)
All BlueSolar models, except the two CAN-bus models BlueSolar MPPT 150/70 and 150/80 CAN-bus
SmartSolar MPPT up to 150/35
5. Battery Chargers
For Skylla TG battery chargers a
Non
inverting
remote on
-
off cable i
s needed
(article number ASS030550200)
For Skylla
-
i battery chargers a
Skylla-
i remote on
-
off cable i
s needed
(article number ASS030550400)
Other battery chargers:
Use a Cyrix-Li-Charge