8
Manual Titan
The Titan charger can remain connected to the battery continuously, without gas formation
taking place, caused by overcharging. It is not necessary to disconnect the battery from the
charger during long time storage, for example during the winter storage of a ship. The Titan
charger will keep your battery in optimum condition under all circumstances and will prolong
the lifetime of your battery.
A parallel load connected to the battery can cause a voltage drop. The Titan charger
automatically switches into the boost-charge mode when the battery voltage drops below the
minimal voltage.
The Titan charger is equipped with a separate starter-battery connection to charge an extra
battery, like a starter-battery. You can use this battery for starting machines, like a boat
engine for this application.
The Titan charger has a stabilised output voltage. Therefore the Titan charger can also be
used as a DC power supply in applications where no battery is present.
2.2 The battery
The Titan charger can charge various batteries. The recommended battery capacity is
indicated in the table below:
Type
Recommended capacity
24/80
300 - 600 Ah
24/100
500 - 1000 Ah
24/100 3-Ph
500 - 1000 Ah
48/50
200 - 400 Ah
The charge voltages of the Titan charger are factory set. Most battery manufactures
recommend these charging voltages for optimal charging of 24V or 48V lead-acid batteries.
It is possible to charge different types of batteries, like traction batteries. To charge these
batteries the charging voltages of the charger have to be changed. Contact your Victron
Energy dealer or battery dealer for more details about the recommended charging voltages.
Содержание SKYLLA-TG 24/100
Страница 2: ......
Страница 3: ...Manual Titan 1 SECTIONS Page English 3 Nederlands 31 Deutsch 59 ...
Страница 85: ...Gebrauchsanweisung Titan 83 Strom Spannungsstabilität 1 1 1 ...