3.2. Setup menu
The setup menu can be entered by pressing “SETUP” during three seconds.
Scrolling text
Icons
Segments
Units
Function or parameter
,
On/off switch
.
-
.
A
Maximum charge current
V
System voltage (read-only)
,
-
Type
Charge algorithm
.
-
.
-
.
V
Absorption voltage
.
-
.
-
.
V
Float voltage
.
-
.
-
.
V
Storage voltage
.
-
.
-
.
V
Equalization voltage
,
Automatic equalization
,
Manual equalization
.
-
Relay function
.
-
.
-
.
V
Low battery voltage alarm set
.
-
.
-
.
V
Low battery voltage alarm clear
.
-
.
-
.
V
High battery voltage alarm set
.
-
.
-
.
V
High battery voltage alarm
clear
-
Relay minimum closed time
(minutes)
.
-
.
-
.
°C mV
Battery temperature
compensation per cell
,
h
Bulk time protection
.
-
.
-
.
h
Absorption time
,
Storage mode
.
-
.
-
.
h
Maximum float time
.
-
.
-
.
h
Repeated absorption time
.
-
.
-
.
Day
Repeated absorption interval
.
-
.
A
Low temperature charge
current
,
Watch function (start-up in
storage if battery voltage >13 V
,
BMS Present
.
-
.
-
.
V
Power supply voltage
.
-
.
A
Input current limit
-
-
The intensity of the backlight
,
,
Backlight automatic turn off
after 60s
-
-
Text scroll speed
,
Buzzer
-
VE.Can device instance
.
Software version
System reset to default
settings
History data reset
,
Lock settings
,
Temperature unit °C/°F
After entering the setup menu, the user can scroll through the menu with the up/down keys.
With select a menu item is entered and the present value is shown. With the up/down keys the user can scroll through the
available modes or increase/decrease the value.
By pressing select again the value/item is set.
Pressing setup shortly will return to the setup menu.
When setup is completed, exit the menu by pressing “SETUP” again three seconds.