7
Adjustments without remote panel
WARNING: Always check with your battery
supplier if the choosen charge characteristic is
suitable for your battery and application
•
Remove the frontplate and disconnect battery
and Voltage sense and Temperature sense and
connect a digital voltmeter to – and +1 output.
Bulk-current
•
While switching on keep both the pushbuttons
⇑
&
⇓
pushed.
•
Release pushbuttons.
•
Bulk LED is flashing alternately with Failure LED.
•
Push
⇑
for up and
⇓
for down.
•
Reading as follows:
Discard first digit of DVM then multiply by 10, i.e:
22.50V => ….2.50 => 25 Amps
15.00V => .....5.00 => 50 Amps
•
Switch the charger Off to store.
Absorption and Float voltage
•
While switching on keep the pushbutton
⇑
pushed for Absorption voltage and
⇓
for Float-
voltage.
•
Release pushbuttons.
•
Absorption or Float LED is flashing alternately
with Failure LED.
•
Push
⇑
for up and
⇓
for down.
•
Reading on voltmeter as is.
•
Switch the charger Off to store.
•
Please note that in adjust-mode the
Temperature sense compensation is not taken
into account.
Warning: If the charger is not switched Off
after an adjustment the new value will not be
stored but will remain on the outputs. After 4
hours the charger continues the normal
sequence with the old values. This can be
useful if a forced high voltage is wanted to get
some life in an assumed ‘dead’ battery.
Return to factory settings
•
Switch the charger on.
•
Keep the pushbutton
⇑
and/ or
⇓
pushed while
switching
off
.
•
The factory settings are restored.
When ready
•
Connect battery and if applicable Voltage sense
and Temperature sense.
•
Replace the frontplate.
20AT
20AT
20AT
20AT
P
E
e
ar
th
c
o
nn
ec
tio
n
N
A
C
in
p
u
t
:
N
eu
tr
al
L
A
C
in
pu
t :
L
in
e
+
ba
tte
ry
1
+
ba
tte
ry
2
-
b
at
te
ry
+
T
ric
kl
e
ch
a
rg
e
-
T
ric
kl
e
c
h
ar
g
e
+
V
o
lta
ge
s
e
ns
e
-
V
o
lta
g
e
se
n
se
+
T
e
m
p
er
a
tu
re
s
e
ns
e
-
T
em
pe
ra
tu
re
s
en
se
R
e
m
o
te
co
n
ne
ct
or
<
=
=
>
Adjusting maximum Bulk current
20AT
20AT
20AT
20AT
P
E
e
a
rt
h
c
o
n
ne
ct
io
n
N
A
C
in
pu
t
: N
e
ut
ra
l
L
A
C
in
p
ut
:
L
in
e
+
ba
tte
ry
1
+
ba
tte
ry
2
-
b
at
te
ry
+
T
ric
kl
e
ch
ar
g
e
-
T
ri
ck
le
c
ha
rg
e
+
V
ol
ta
g
e
se
ns
e
-
V
o
lta
ge
s
e
n
se
+
T
em
pe
ra
tu
re
s
en
se
-
T
e
m
p
e
ra
tu
re
s
e
ns
e
R
em
o
te
co
nn
ec
to
r
<
=
=
>
Adjusting Float voltage
20AT
20AT
20AT
20AT
P
E
e
a
rt
h
c
o
n
ne
ct
io
n
N
A
C
in
pu
t
: N
e
ut
ra
l
L
A
C
in
p
ut
:
L
in
e
+
ba
tte
ry
1
+
ba
tte
ry
2
-
b
at
te
ry
+
T
ric
kl
e
ch
ar
g
e
-
T
ri
ck
le
c
ha
rg
e
+
V
ol
ta
g
e
se
ns
e
-
V
o
lta
ge
s
e
n
se
+
T
em
pe
ra
tu
re
s
en
se
-
T
e
m
p
e
ra
tu
re
s
e
ns
e
R
em
o
te
co
nn
ec
to
r
<
=
=
>
Adjusting Absorption voltage
20AT
20AT
20AT
20AT
P
E
e
a
rt
h
co
n
ne
ct
io
n
N
A
C
in
p
ut
: N
e
ut
ra
l
L
A
C
in
pu
t :
L
in
e
+
ba
tte
ry
1
+
ba
tte
ry
2
-
b
at
te
ry
+
T
ric
kl
e
ch
a
rg
e
-
T
ri
ck
le
c
h
ar
ge
+
V
ol
ta
ge
s
en
se
-
V
ol
ta
g
e
se
n
se
+
T
em
pe
ra
tu
re
s
en
se
-
T
e
m
p
er
a
tu
re
s
e
ns
e
R
em
ot
e
co
nn
ec
to
r
<
=
=
>
Restoring defaults
Содержание Phoenix 12/30
Страница 98: ...94 GB NL F D I DK ΕΛ N P E S Specs ...