6
5. Technical data
Phoenix Inverter
12 Volt
24 Volt
48 Volt
12/250
24/250
48/250
12/375
24/375
48/375
Cont. power at 25 °C
(1)
250 VA
375 VA
Cont. power at 25 °C / 40 °C
200 / 150 W
300 / 250 W
Peak power
350 W
700 W
Output AC voltage / frequency (adjustable)
230 VAC +/- 3% 50Hz or 60Hz +/- 0,1%
Input voltage range
9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0 VDC
Low battery shut down (adjustable)
9,3 / 18,6 / 37,2 VDC
Low battery restart & alarm (adjustable)
10,9 / 21,8 / 43,6 VDC
Battery charged detect (adjustable)
14,0 / 28,0 / 56,0 VDC
Max. efficiency
87 / 88 / 88 %
89 / 89 / 90 %
Zero-load power
4,2 / 5,2 / 7,9 W
5,6 / 6,1 / 8,5 W
Default zero-load power in ECO mode
(default search interval: 2,5 s, adjustable)
0,8 / 1,3 / 2,5 W
0,9 / 1,4 / 2,6 W
ECO mode stop and start power setting
25 W
Protection
(2)
a - f
Operating temperature range
-40 to +60°C (fan assisted cooling)
(derate 3% per °C above 40°C)
Humidity (non condensing)
max 95%
ENCLOSURE
Material & Colour
Steel chassis and plastic cover (blue Ral 5012)
Battery-connection
Screw terminals
Maximum cable cross-section
10 mm² / AWG8
10 mm² / AWG8
Standard AC outlets
Schuko (CEE 7/4), IEC-320 (male plug included)
UK (BS 1363), AU/NZ (AS/NZS 3112)
Protection category
IP 21
Weight
2,4 kg / 5,3 lbs
3,0 kg / 6,6 lbs
Dimensions (hxwxd, mm)
(hxwxd, inch)
86 x 165 x 260
3,4 x 6,5 x 10,2
86 x 165 x 260
3,4 x 6,5 x 10,2
ACCESSORIES
Remote on-off
Yes
Automatic transfer switch
Filax
STANDARDS
Safety
EN/IEC 60335-1 / EN/IEC 62109-1
EMC
EN55014-1 / EN 55014-2
IEC 61000-6-1 / IEC 61000-6-3
Automotive Directive
2004/104/EC EN 50498
1) Nonlinear load, crest factor 3:1
2) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) DC ripple too high
Содержание Phoenix 12/250
Страница 2: ......
Страница 9: ...EN NL FR DE ES Appendix the Digital Multi Control Fig 1 Front and rear view FigFi...