8
OUTPUT led indicator
INPUT led indicator
LED indicators
The Buck-Boost DC-DC converter is equipped with two RGB LEDs.
The
IN
LED has the following functions:
Green: The converter is switched on (by the engine running detection, or by applying a voltage on pin 1).
Yellow: The input voltage is lower than the set threshold to allow the converter
to switch on.
Red: The internal temperature is higher than the set safety threshold. The converter is
switched on
Blue: Short light pulses = the engine running detection is active, the converter turns on after a delay.
Flashes slowly = the converter is switched off and blocked for switching on due to
A too low input voltage.
The
OUT
LED has the following functions:
Green: The converter is switched off. The connected battery has a correct terminal voltage.
Yellow: The converter is switched off. The connected battery has too low a terminal voltage.
Red: The converter is switched off. The connected battery is empty or the battery is not connected.
Purple: The converter is switched on and supplies power to the connected battery and/or electrical
consuming points.
Flashing purple: The converter is switched off. When the converter starts up, the set voltage of the
second battery is too low (safety circuit 31 is active).
The normal alerts of each LED blinks slowly for power saving (Setting 27).
Engine running detection
The converter has a unique engine running detection in order to be able to detect a running vehicle
engine. This prevents the converter from charging the starter battery if the alternator does not supply
power.
The converter is switched on:
When the engine is running and the supply voltage is >= (adjustable) volts
and
any (adjustable) minute
blocking is over.
Pin 1 input (as an alternative to the engine running detection)
The converter may also be switched on with a switch or relay contact.
Switch on:
The converter is switched on:
If pin 1 input >= 2 volts,
and
the supply voltage is >= (adjustable) volts
and
any blocking is over.
Important when installing!
Basic settings
At the time of commissioning, the following basic settings shall be applied:
Setting
12V – 12V
24V – 24V
12V – 24V
20 Output voltage
14.4V
28.8V
28.8V
22 Maximum output current
60% of the current supplied by the vehicle’s alternator (max.)
24 Undervoltage threshold
11.8V – 12.2V
23.8V – 24.2V
11.8V – 12.2V
Содержание ORI303100000
Страница 2: ......
Страница 64: ...2 Windows TSConfig TSConfig TSConfig https www victronenergy com support and downloads software 25A 50A 100A...
Страница 65: ...3 EN NL FR DE SE RU Appendix...
Страница 66: ...4...
Страница 67: ...5 EN NL FR DE SE RU Appendix...
Страница 68: ...6...
Страница 69: ...7 EN NL FR DE SE RU Appendix OUT GND IN IN GND GND OUT Pin 1 Pin 2 1 2 Buck boost 3 1 2 OUT GND IN USB CAN Bus...