More on batteries and charging
Our book ‘Energy Unlimited’ offers further information on batteries and battery charging, and is available free of charge on our
website (see www.victronenergy.com → Support & Downloads’ → General Technical Information). For more information on
adaptive charging, please also refer to the General Technical Information on our website.
2.3. Self consumption – solar energy storage systems
When the MultiPlus is used in a configuration in which it will feed back energy to the grid it is required to enable grid code
compliance by selecting the grid code country setting with the VEConfigure tool.
Once set, a password will be required to disable grid code compliance or change grid code related parameters.
If the local grid code is not supported by the MultiPlus an external certified interface device should be used to connect the
MultiPlus to the grid.
Special note for Australian customers: IEC62109.1 certification and CEC approval for off-grid use does NOT imply approval for
grid-interactive installations. Additional certification to IEC 62109.2 and AS 4777.2.2015 are required before grid-interactive
systems can be implemented. Please check Clean Energy Council website for current approvals.
MultiPlus 2kVA 120V
Page 3
Description