EN
Appe
nd
ix
Problem
Cause
Solution
The charger is
not functioning
The AC input voltage or
frequency is out of range.
Ensure that the input voltage
is between 95 Vac and 140
Vac, and that the frequency
matches the setting.
The battery is not
being charged
fully.
Incorrect charging current.
Set the charging current at
between 0.1 and 0.2x battery
capacity.
A defective battery
connection.
Check the battery terminals.
The absorption voltage has
been set to an incorrect
value.
Adjust the absorption voltage
to the correct value.
The float voltage has been
set to an incorrect value.
Adjust the float voltage to the
correct value.
The internal DC fuse is
defective.
Inverter is damaged.
The battery is
overcharged.
The absorption voltage has
been set to an incorrect
value.
Adjust the absorption voltage
to the correct value.
The float voltage has been
set to an incorrect value.
Adjust the float voltage to the
correct value.
A defective battery.
Replace the battery.
The battery is too small.
Reduce the charging current
or use a battery with a higher
capacity.
The battery is too hot.
Connect a temperature
sensor.
Battery charge
current drops to 0
when the
absorption
voltage is
reached
Alt. 1: Battery
overtemperature
(> 50°C)
- Allow battery to cool down
- Place battery in a cool
environment
- Check for shorted cells
Alt 2: Battery temperature
sensor faulty
Unplug battery temperature
sensor from the Multi.
Reset the Multi by switching it
off, then wait for 4 seconds
and switch it on again
If the Multi now charges
normally, the battery
temperature sensor is faulty
and needs to be replaced
Содержание MultiPlus 12/3000/120-16
Страница 1: ...Manual EN Appendix MultiPlus Compact 12 2000 80 50 120V 24 2000 50 50 120V ...
Страница 2: ......
Страница 3: ......
Страница 34: ......
Страница 35: ...EN Appendix www victronenergy com APPENDIX A Connection overview ...
Страница 37: ...EN Appendix www victronenergy com APPENDIX B Installation information ...
Страница 38: ...APPENDIX C Parallel connection APPENDIX D Three phase connection ...
Страница 39: ...EN Appendix www victronenergy com APPENDIX E split phase connection ...
Страница 42: ......
Страница 43: ...www victronenergy com 255m m 125m m 520m m 95mm ...