1.3
Transport and storage
On storage or transport of the product, ensure that the battery leads are disconnected.
No liability can be accepted for damage in transit if the equipment is not transported in its
original packaging.
Store the product in a dry environment; the storage temperature should range from –20°C to
60°C.
1.3.1
Storage instructions of Lithium batteries
Store the Lithium batteries always fully charged.
Check the voltage of the stored Lithium battery periodically. If the voltage is dropped below
24V, recharge it. Because of the battery management electronics there is always a leakage
current which will eventually empty the battery. The weekly consumption of the BMS inside
a 24V/180Ah battery, when not connected to the Lynx Ion + Shunt, is approximately 2Wh
per week.
1.3.2
Storage instructions of a complete system (Lithium batteries with Lynx)
Lithium batteries will permanently damage when fully drained. The system has a small self-
discharge which needs to be taken into account when storing the system. It is best to
always store the batteries fully charged.
When storing a complete system, make sure that the Lynx Ion + Shunt is set in standby
mode (for instructions see chapter 6).
•
Standby consumption 24V Systems: 73mW for the Lynx Ion + Shunt (standby).
•
Standby consumption 48V systems: 139mW for the Lynx Ion + Shunt (standby).
Two calculation examples:
•
A full single 24Volt battery connected to a Lynx Ion + Shunt which is in standby
will last approximately 2570 days. The same system, but then automatically
switched to standby mode due to under voltage will last approximately 128 days.
•
A full 48Volt system with two batteries in series, connected to a Lynx Ion + Shunt
which is in standby will last approximately 2700 days. The same system which
has automatically disconnected and switched to standby mode due to under
voltage will last approximately 135 days.
Содержание Lynx Ion + Shunt 350
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 9: ......
Страница 10: ......
Страница 12: ......
Страница 14: ......
Страница 15: ......
Страница 17: ...4 Configure the Lynx Ion BMS Support assistant as follows ...
Страница 23: ......
Страница 24: ...Front view I G H J ...
Страница 25: ......
Страница 28: ......
Страница 29: ...Distributor Serial number Version 1 Date 10 June 2014 ...