21
No changes can be made in the
setup-mode
- Check if the setup-lock is
OFF
(Function F20)
- Your BMV-501 might be locked
by the super- lock. Ask the
installer for the password to
unlock the monitor using the
PC-link.
Not all readouts in normal mode
can be selected
- Installer has cancelled some
parameter readouts using the
administrator software with the
PC-link.
‘CHARGE BATTERY’ or
‘CHARGE BATTERY FULL’
keeps on flashing
- Charge battery full
(equalize/synchronize your
battery with the monitor)
- Check the charged-parameters
in Functions F02, F03 and F04
for possible wrong settings.
State-of-charge and/or time-to-
go readout not accurate
- Check if all current is flowing
through the shunt (the negative
terminal of the battery may only
contain the wire going to the
battery-side of the shunt!).
- Current sense leads from the
shunt are reversed.
- Check battery capacity in
Function F01
- Check CEF in Function F09
- Check Peukert Exponent in
Function F10
- Check Battery temperature in
Function F11
- Check Temperature coefficient
in Function F12
Display returns ‘- - - -‘ in
temperature readout
- Connection with temperature
sensor is lost. Check for failed
connections and/or cable
damage.
Battery voltage readout is highly
inaccurate
- Check prescaler setting in
Function F16
If none of the above remedies will help to solve the problem you
encounter, it’s best to contact your local dealer for further help.