F06 : Low-battery alarm OFF. When the state-of-charge percentage
has risen above this value and the alarm relay is activated,
the alarm relay will be deactivated again. When
FULL
is
selected the alarm relay is deactivated when the charged-
parameters are met.
Default : 80.0%
Range : 0.0 – 100.0% / FULL
Stepsize : 1.0%
F07 : Undervoltage alarm. When the battery voltage falls below this
value, after 10 seconds the message
Lo
shall appear on the
display and the alarm relay will be activated.
Default : 10.5V
Range : OFF / 8.0 – 33.0V
Stepsize : 0.1V
F08 : Overvoltage alarm. When the battery voltage rises above this
value, after 5 seconds the message
Hi
shall appear on the
display and the alarm relay will be activated.
Default : 16.0V
Range : OFF / 10.0 – 35.0V
Stepsize : 0.1V
F09 : Charge-efficiency-factor (CEF). It is recommended to keep
this value at
AU
(automatic calculation). The value
A90
resets
the automatic calculation to 90%. A manual setting is
represented by
Uxx
where
xx
is the charge-efficiency. (see
chapter 2.1 for more info about CEF)
Default : AU
Range : U50 – U99 / AU / A90
Stepsize : 1%
F10 : Peukert exponent (discharge efficiency). When unknown it is
recommended to keep this value at
1.25
. A value of
1.00
disables the Peukert compensation. See chapter 2.2 for more
information and a calculation example to calculate your
battery’s Peukert exponent.
Default : 1.25
Range : 1.00 – 1.50
Stepsize : 0.01