![Victron energy Blue Power BMV-602 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/victron-energy/blue-power-bmv-602/blue-power-bmv-602_manual_1014783021.webp)
17
www.victronenergy.co
m
4
TECHNICAL DATA
Supply voltage range
9 ... 95VDC
Supply current (no alarm condition)
@Vin=24VDC without back lighting
<1 mA
@Vin=12VDC without back lighting
<1 mA
Input voltage range auxiliary battery
9 ... 95VDC
Input current range
-500 ... +500A
Battery capacity range
20 ... 9999Ah
Operating temperature range
0 ... 50
C
Readout resolution:
Voltage (0 ... 135V)
voltage dependent
Current (0 ... 10A)
0.1A
Current (10 ... 500A)
1A
Amp hours (0 ... 200Ah)
0.1Ah
Amp hours (200 ... 2000Ah)
1Ah
State-of-charge (0 ... 100%)
0.1%
Time-to-go (0 ... 100hrs)
1minute
Time-to-go (100 ... 240hrs)
1hr
Voltage measurement accuracy
0.3%
Current measurement accuracy
0.5%
Potential free alarm contact
Mode
Normally open
Rating
60V/1A max.
Dimensions:
Front panel
69 x 69mm
Body diameter
52mm
Overall depth
31mm
Net weight:
BMV
70g
Shunt
315g
Material
Body
ABS
Sticker
Polyester