13
www.victronenergy.co
m
Rlc:
Clear relay low voltage.
When the battery voltage rises above this
value, the alarm relay will be de-activated. This value needs to be
greater than or equal to Rl.
Rh:
Relay high voltage.
When the battery voltage rises above this
value for more than 10 seconds the alarm relay will be activated.
Rhc:
Clear relay high voltage.
When the battery voltage falls below this
value, the alarm relay will be de-activated. This value needs to be
less than or equal to Rh.
BLI:
Intensity backlight.
The intensity of the backlight, ranging from 0
(always off) to 9 (maximum intensity).
D V:
Battery voltage display.
Determines if the battery voltage is
available in the monitoring menu.
D I:
Current display.
Determines if the current is available in the
monitoring menu.
D CE:
Consumed energy display.
Determines if the consumed energy
is available in the monitoring menu.
D SOC:
State-of-charge display.
Determines if the state of charge is
available in the monitoring menu.
D TTG:
Time-to-go display.
Determines if the time to go is available in
the monitoring menu.
ZERO:
Zero current calibration.
If the BMV reads a non-zero current
even when there is no load and the battery is not charging, this
option can be used to calibrate the zero reading. Ensure that there
really is no current flowing into or out of the battery, then hold the
select button for 5 seconds.
SYNC:
Manual synchronization.
This option can be used to manually
synchronize the BMV. When the battery is fully charged, hold the
select button for 5 seconds. Note: If the BMV fails to automatically
synchronize, check the wiring, and ensure that Cb, Vc, It, and Tcd
are set correctly.
R DEF:
Reset to factory defaults.
Reset all settings to the factory
defaults by holding the select button for 5 seconds.
Cl HIS:
Clear historic data.
Clear all historical data by holding the select
button for 5 seconds.
Lock:
Setup lock.
When on, all settings (except this one) are locked and
cannot be altered.
SW:
Firmware version
(cannot be altered).