background image

  

Manual Skylla with universal input  

11 

3. 

DIRECTIONS FOR USE 

3.1 

Installation 

Find  a  dry  and  well-ventilated  area  to  mount  the  Skylla  charger  and  battery.  Keep  the 
distance between the charger and the battery less than 6 meters. 
The  charger  may  be  wall  or  floor  mounted.  Mounting  on  a  wall  improves  the  air 
circulation within the charger cabinet and will prolong the lifetime of the battery charger. 
The holes for the mains cable, the battery connections, the remote connections and the 
earth  connection  are  located  at  the  bottom  of  the  battery  charger  housing,  see 
illustration 2. 
 

 
 
 
 
 
 
 
 
 

Connecting earth

 

Connect the earth screw to a real earth-point. Connections to earth have to be according 
to applicable safety standards. 

 

On a ship: Connect the earth screw to the earth plate or to the hull of the ship. 

 

On land: Connect the earth screw to the earth of the mains. 

 

Mobile  applications  (a  vehicle,  a  car  or  a  caravan):  Connect  the  earth  screw  to  the 
frame of the vehicle. 

 

 

 

 

 

 

Connecting the battery

 

The  connections  between  the  Skylla  charger  and  the  battery  are  essential  for  a  good 
operation  of  the  charger.  Therefore  the  battery  connections  need  tightening  well.  It  is 
important to use short and thick battery cables to minimise the voltage losses in the cable. 
Cable  resistance  decreases  accordingly  as  the  cables  become  shorter  and  thicker. 
Therefore  it  is not  recommended  to  use  cables  longer  than  6  meters.  The  table below 
shows the recommended cable core thickness.

 

 

Type 

core diameter of cables until 1,5m 

core diameter of cables between 1,5m and 6m 

24/30 

6 mm

2

 

10 mm

2

 

24/50 

10 mm

2

 

16 mm

2

 

24/100 

35 mm

2

 

50 mm

2

 

Illustration 2,  
Location of the charger 
connection holes

 

 

Hole for the 
negative 
battery cable

Hole for the 
positive 
battery cable

M6 Earth 

stud

Hole for the

mains cable

Hole for the starter

battery cables

Hole for the
remote cable

 

Содержание 24/30

Страница 1: ...USER MANUAL SKYLLA TG 24 30 with Universal Input SKYLLA TG 24 50 with Universal Input SKYLLA TG 24 100 G with Universal Input SKYLLA TG 24 100 victron energie C H AR G ER...

Страница 2: ......

Страница 3: ...ANYONE FOR SPECIAL COLLATERAL INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING OUT OF PURCHASE OR USE OF THESE VICTRON ENERGY PRODUCTS THE SOLE AND EXCLUSIVE LIABILITY TO VICTRON ENER...

Страница 4: ...3 Adjusting the equalize charging mode time 18 4 4 Diode splitter charge voltage compensation 18 4 5 Traction battery compensation 19 4 6 Use as a power supply 19 4 7 Use of a temperature sensor 19 4...

Страница 5: ...ystem can consist of a Victron Energy inverter a Victron Energy battery charger if required a Victron Energy Mains Manager and batteries with sufficient capacity Our equipment can be used in numerous...

Страница 6: ...ff switch at the front of the cabinet does not switch off the mains supply Disconnect the mains supply before making or breaking the connections to the battery Do not use the voltage sense facility in...

Страница 7: ...TG charger commences charging in the boost charge mode In this mode the battery is charged until the battery voltage reaches the boost voltage At this point the battery is charged to approximately 80...

Страница 8: ...e a starter battery You can use this battery for starting machines like a boat engine for this application The Skylla TG charger has a stabilised output voltage Therefore the Skylla TG charger can als...

Страница 9: ...the output voltage approaches 0 Volt The battery charger resumes normal operation when the short circuit is removed The short circuit current can also be reduced by the Victron Energy COV panel Input...

Страница 10: ...LED illuminates continuously The charger resumes operation when the internal temperature is restored within limits Voltage sense protection When the voltage sense facility is used the charger automat...

Страница 11: ...he earth screw to the earth of the mains Mobile applications a vehicle a car or a caravan Connect the earth screw to the frame of the vehicle Connecting the battery The connections between the Skylla...

Страница 12: ...ative battery cable to the connection tool see illustration 3 Check if the green led illuminates see illustration 3 If not the positive and negative battery cables have been reversed Disconnect the co...

Страница 13: ...charger Remove the front of the battery charger to access the AC input connector Connect the mains PE cable green yellow to the AC input connector located on the circuit board see illustration 4 Conne...

Страница 14: ...of the battery the charger will start in the boost charge mode or at float charge mode If the battery is not full the boost led illuminates and the charger will start boost charging the battery A dip...

Страница 15: ...charger does not have to be switched off and the batteries can stay connected to the battery charger 3 3 Maintenance The Skylla charger does not require any specific maintenance However an annual che...

Страница 16: ...the battery charger Adjustments can be made by means of turning a potentiometer or by changing the position of a switch on the DIP switch See illustration 7 for the location of the DIP switch and the...

Страница 17: ...set float and boost voltage The boost voltage is always higher than the float voltage These charging voltages are the recommended values from almost every battery manufacturer Before adjusting the cha...

Страница 18: ...duration of the equalize charge mode can be changed to fit the specifications of the battery The duration of the equalize charge mode can be set to 0 4 8 or 12 hours When selecting 0 hours the charger...

Страница 19: ...the above mentioned procedure the output voltage range is limited When the full output voltage range is required please contact your Victron Energy dealer See chapter 6 3 for details 4 7 Use of a tem...

Страница 20: ...s Connect a red 0 75 mm2 wire to the positive battery pole and the Vse connector of the charger see illustration 8 Connect a black 0 75 mm2 wire between the negative pole of the battery and the Vse co...

Страница 21: ...ging current of 30A 50A or 100A according to the model can be limited with an external panel This panel the Victron Energy COV panel contains an adjustable potentiometer Limiting the maximum charging...

Страница 22: ...ol to the POT and POT connector 4 12 Connecting a remote on off switch A remote switch can be connected to the charger so the charger can be switched on and off from a remote location To operate the s...

Страница 23: ...e between the connection of the voltmeter and VM at the remote connector Connect a red wire between the connection of the voltmeter and VM at the remote connector Connect the mains voltage 4 15 Connec...

Страница 24: ...ut fuses The battery is being overcharged The battery charger is set into the permanent boost charge mode Deselect the permanent boost DIP switch Rboost The boost charge voltage is set to a wrong valu...

Страница 25: ...on EN 55014 1993 EN 61000 3 2 1995 EN 61000 3 3 1995 Immunity EN 55104 1995 Vibration IEC 68 2 6 1982 Safety GL approval EN 60335 2 29 1991 Environmental category C EMC 1 Certificate no 54 758 08HH 6...

Страница 26: ...n for traction battery via DIP switch 2 0 V 2 0 V 2 0 V Maximum output current 30A 50A 100A Output current range 0 30A 0 50A 0 100A Output voltage ripple measured with a 30A 50A or 100A resistive load...

Страница 27: ...ght including box 6 4 Kg 10 5 Kg Input 230Vac connection Connection block suitable for wires up to 4 mm Connection block suitable for wires up to 4 mm Battery connection M8 bolts M8 bolts Earth connec...

Страница 28: ...al input victron energy b v Pallas TG 12 50 Skylla TG 24 30 24 30 110Vac Skylla TG 24 50 and Titan 48 25 dimensions drawing no TI010000 date 120204 revision 0002 220 15 7 8 6 250 25 200 140 90 365 309...

Страница 29: ...kylla with universal input 29 victron energy b v Skylla TG 24 80 24 100 and Titan 48 50 dimensions drawing no TI020000 date 220703 revision 01 220 8 6 250 200 250 25 25 23 365 309 200 All measurements...

Страница 30: ...Skylla with universal input Victron Energy B V The Netherlands Phone 31 0 36 535 97 00 Fax 31 0 36 531 16 66 E mail sales victronenergy com Internet site http www victronenergy com Version rev03 Date...

Отзывы: