Proper installation is the first step to operation.  We recommend that your Refrigerator or Freezer be installed by an
authorized Victory Certified Installer.

Receiving Shipment

All units are performance tested and thoroughly inspected prior to shipment.  Upon leaving the factory, all units are in
perfect condition. Upon receipt, examine the exterior of the shipment packaging for any signs of rough handling. If the
cabinet is damaged, it should be noted on the delivery slip or bill of lading and signed.  A claim must be filed immediately
against the carrier indicating the extent and estimated cost of damage incurred.

Uncrating

Tools Needed

3/4” Box Wrench  

Adjustable Wrench  

Level

WARNING:  

Never lay your refrigerator or freezer down on either its back, front or sides. This allows compressor oil into

the refrigerant lines which can damage the compressor at start-up.  If the unit is laid down, it must be set upright for a
minimum of 12 hours before starting the compressor.  Failure to adhere to the above recommendation will void the warranty.  

1.   

Remove and discard all cardboard crating, packaging material, tape and interior components.

2.   

Move cabinet as close to final location as possible before removing skid.

3.  

Remove the shipping skid by tipping the cabinet forward.  Remove the shipping bolts with 3/4” box wrench while
the cabinet is held in one direction.  Repeat this procedure while the cabinet is held in the opposite direction.

4.

Use extreme caution when removing the wooden skid, especially when the last bolt is removed.  If not properly
blocked, the skid will fall to the floor.

Locating Your New Undercounter Refrigerator or Freezer

Consider the following when selecting a location cabinet:

1. Clearance - 

Undercounter refrigerator or freezer cabinets do not require a clearance between the back of the cabinet

and neighboring wall.  The front grill is designed to guarantee sufficient air circulation to the condensing unit.  However,
it will greatly improve the cabinet's ability to be consistently energy efficient if there is air flowing through the slates of
the rear grill that conceals the condensing unit.

2. Floor Load - 

The floor on which the cabinet will rest must be free of vibration and suitably strong enough to support

the combined weights of the cabinet plus the maximum product load.  

3. Ventilation - 

The air cooled, self-contained refrigeration system requires a sufficient amount of cool, clean air.  Avoid

placing the refrigerator or freezer cabinet near heat generating equipment such as ovens, ranges, heaters, fryers,
steam kettles, etc., and out of direct sunlight.  Avoid locating the self-contained refrigerator cabinet in an unheated
room, or where the room temperature may be below 55

°

F.

Installing Casters

Undercounter refrigerator or freezer cabinets are shipped with single stud mounted casters.  Refer to installation
instructions that are packed with casters.

Leveling

Cabinets must be leveled when installed. Failure to level your cabinet may result in doors not sealing, closing properly or
condensate water not draining properly. Refer to leveling instructions that are packed with casters.  

INSTALLATION INSTRUCTIONS

Содержание RUFS-1D-S7

Страница 1: ...one 856 428 4200 Fax 856 428 7299 Website www victory refrig com E Mail parts victory refrig com order entry victory refrig com service victory refrig com For Models RURS 1D S7 RUFS 1D S7 Recessable U...

Страница 2: ...428 4200 IMPORTANT INFORMATION PLEASE READ Please read these instructions carefully before installing or using If recommended procedures are not followed warranty claims will be denied Your Warranty...

Страница 3: ...result from the use or misuse by Buyer its employees or others of the equipment supplied hereunder and Buyer s sole and exclusive remedy against Seller for any breach of the foregoing warranty or othe...

Страница 4: ......

Страница 5: ...ng the wooden skid especially when the last bolt is removed If not properly blocked the skid will fall to the floor Locating Your New Undercounter Refrigerator or Freezer Consider the following when s...

Страница 6: ...wire be installed from the main supply to your refrigerator or freezer To assure that the correct voltage is being supplied while the refrigerator or freezer is in operation take a voltage reading at...

Страница 7: ...et running efficiently it is recommended that you clean the condenser once every three months However once a month is recommended if the unit is located near cooking equipment which produces grease la...

Страница 8: ...or frozen closed 3 Excessive heat load placed into cabinet 4 Prolonged or too frequent door openings 5 Evaporator coil iced 6 Restriction in refrigeration system 7 Dirty condenser 8 Filter dirty 1 Cl...

Страница 9: ...nt or is oversized 1 Restriction in dehydrator or strainer 2 Liquid shut off king valve partially closed 1 Loose parts or mounting 2 Tubing rattle 3 Bent fan blade causing vibration 4 Fan motor bearin...

Страница 10: ......

Страница 11: ......

Страница 12: ...Self Contained Undercounter Refrigerator 115V 60HZ 1Ph...

Страница 13: ...Self Contained Undercounter Freezer 115V 60HZ 1Ph...

Отзывы: