LIMITED WARRANTY

(Continental USA Only)

The Seller warrants to the original purchaser, equipment manufactured by Seller to be free from defects in material 

and workmanship for which it is responsible. The Seller’s obligation under this warranty shall be limited to replacing 

or repairing at Seller’s option, without charge, F.O.B. Seller’s factory, any part found to be defective and any labor 

and material expense incurred by Seller in repairing or replacing such part, such warranty to be limited to a period of 

twelve (12) months from the date of installation, provided, however, installation occurs within six months of date of 

purchase and equipment is in normal use and service and is installed in accordance with manufacturer’s 

recommendations and provided terms of payment have been fully met. All labor shall be performed during regular 

working hours. Overtime premium charges will be at Buyer’s expense. 

Proof of purchase must be supplied to Seller to validate warranty. This warranty is valid only if equipment is properly 

installed, started-up and inspected by the dealer or authorized Victory Service agent.

Removal or alteration of the serial/data plate from any equipment shall be deemed to release Seller from all warranty 

obligations or any other obligations, expressed or implied.

This warranty does not cover Thermostat or Defrost Timer calibration and/or adjustment, freight damage, normal 

maintenance items outlined in Owner’s Manual, adjustment of door mechanisms or replacement of light bulbs, fuses 

or batteries. The warranty does not cover installation, start-up, normal maintenance, food loss, or other consequential 

damage. 

Any repairs or replacement of defective parts shall be performed by Seller’s authorized service personnel. Seller 

shall not be responsible for any costs incurred if the work is performed by other than Seller’s authorized service 

personnel. Reimbursement claims for part(s) or labor service costs must be made in writing. Model, cabinet serial 

numbers and installation location must be shown on the claim. A receipted bill from the servicing agency must 

accompany the claim, together with full details of the service problems, diagnosis and work performed. Victory 

reserves sole discretion whether further documentation on a claim is to be submitted.

Seller shall not be liable for consequential damages of any kind which occur during the course of installation of 

equipment, or which result from the use or misuse by Buyer, its employees or others of the equipment supplied 

hereunder, and Buyer’s sole and exclusive remedy against Seller for any breach of the foregoing warranty or 

otherwise shall be for the repair or replacement of the equipment or parts thereof affected by such breach.

The foregoing warranty shall be valid and binding upon Seller if and only if Buyer loads, operates and maintains the 

equipment supplied hereunder in accordance with the instruction manual provided to Buyer. Seller does not 

guarantee the process of manufacture by Buyer or the quality of product to be produced by the equipment supplied 

hereunder and Seller shall not be liable for any prospective or lost product or profits of Buyer.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED 

WARRANTIES WHATSOEVER. SPECIFICALLY THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY 

OR OF FITNESS FOR A PARTICULAR PURPOSE.

The foregoing shall be Seller’s sole and exclusive obligation and Buyer’s sole and exclusive remedy for any action, 

whether in breach of contract or negligence. In no event shall Seller be liable for a sum in excess of the purchase 

price of the item.

You may register online at 

www.victory-refrig.com, 

fax this completed page to 

(856) 673-0038

, or copy and mail form below to Victory. 

NOTE:   The following mail-in form or online registration must be filled out and forwarded to Victory by the installer or customer   

 

within 10 days after start-up. Failure to do this will invalidate the warranties. Retain this information for your records.

WARRANTIES NOT VALID UNLESS REGISTERED AT 

FACTORY WITHIN 10 DAYS AFTER START-UP DATE.

ORIGINAL DATE OF INSTALLATION
CUSTOMER/END USER NAME
STREET
DEALER'S NAME
STREET

PHONE

CITY

STATE

ZIP CODE

PHONE

CITY

STATE

ZIP CODE

110 WOODCREST ROAD

CHERRY HILL, NJ 08003-3648                  

TEL: (856) 428-4200  : FAX: (856) 673-0038

Cabinet Model No.

Cabinet Serial No.

(Data plate information located inside cooler on the upper left wall)

Содержание FS-1D-S7

Страница 1: ...est Road Cherry Hill NJ 08003 Phone 856 428 4200 Fax 856 428 7299 Website www victory refrig com E Mail parts victory refrig com order entry victory refrig com service victory refrig com VR 1 VR 2 VR 3 VF 1 VF 2 VF 3 RS 1D S7 RS 2D S7 RS 3D S7 FS 1D S7 FS 2D S7 FS 3D S7 Manual Part No 50707403 Rev 1A Print Date 09 14 10 ...

Страница 2: ...stalling or using If recommended procedures are not followed warranty claims will be denied Your Warranty Registration information is located on the next page of this manual Please complete the card and submit it to Victory Refrigeration within 10 days of installation Failure to properly register equipment can void the warranty Victory Refrigeration reserves the right to change specifications and ...

Страница 3: ...e claim together with full details of the service problems diagnosis and work performed Victory reserves sole discretion whether further documentation on a claim is to be submitted Seller shall not be liable for consequential damages of any kind which occur during the course of installation of equipment or which result from the use or misuse by Buyer its employees or others of the equipment suppli...

Страница 4: ......

Страница 5: ...oid the warranty 1 Split plastic wrap along one of the cardboard posts Remove and discard all packaging material tape and interior components 2 Move cabinet as close to final location as possible before removing skid 3 Remove the shipping skid by tipping the cabinet forward Remove the shipping bolts with 3 4 box wrench while the cabinet is held in one direction Repeat this procedure while the cabi...

Страница 6: ...he other casters legs Leveling Cabinets must be leveled when installed Failure to level your cabinet may result in doors not sealing closing properly or condensate water not draining properly Casters Cabinets with casters can be leveled by placing large flat washers in between 1 2 stud and holes located on the case bottom Legs Rotate the foot of the leg with an adjustable wrench to achieve desired...

Страница 7: ...being supplied while the refrigerator or freezer is in operation take a voltage reading at the motor compressor electrical connections or as close to the motor compressor as possible All refrigerator or freezer electrical systems are internally grounded Temperature Control Temperature control should be set to maintain a temperature of 38 F 3 3 C to 40 F 4 4 C for refrigerators and 3 F 19 4 C to 3 ...

Страница 8: ...for leaks Make sure refrigeration lines are not dented kinked or rubbing Check condenser fan for freedom to rotate without striking any stationary members Check that cabinet is level Product Load After the refrigerator or freezer has been started and reaches the proper storage temperatures food may be loaded For optimum energy efficiency we recommend allowing a 1 1 2 clearance between the interior...

Страница 9: ...binet 50293701 Accumulator 2 3 Section Refrigerator Freezer 1 per cabinet 50599402 Defrost Heater Safety Switch 1 per cabinet freezer only 50909501 Defrost Heater 1 Section Freezer 115V 300W 1 per cabinet freezer only 50909601 Defrost Heater 2 3 Section Freezer 115V 600W 1 per cabinet freezer only 50617102 Evaporator Coil 84E10 1 Section Refrigerator 1 per cabinet 50616802 Evaporator Coil 84E21 2 ...

Страница 10: ...all shelves 7 Return power electrical to unit by resetting circuit breaker 8 Return food to cabinet when temperature indicator reaches safety zone Condenser Maintenance To keep your cabinet running efficiently it is recommended that you clean the condenser once every three months However once a month is recommended if the unit is located near cooking equipment which produces grease laden vapors i ...

Страница 11: ...ich never need to be oiled Installing Replacement Door Gasket if required Removing Beginning at one corner pry gasket loose from the retaining strip Peel remainder of gasket from the door and discard Replacing Before replacing be sure the gasket and door are at room temperature If necessary soak the gasket in warm water to make it more pliable Align new gasket frame on the door retainer strip Star...

Страница 12: ...ser coil Make sure door is closed when not in use Avoid prolonged door open ings Dirty condenser coil Clean the condenser coil Insufficient clearance around cabinet or exces sively high ambient temperature Insure adequate air space relocate away from heat generating equip ment ovens fryers heating ducts etc and out of direct sunlight Evaporator coil blocked with ice Turn unit off and allow coil to...

Страница 13: ...NOTES xi ...

Страница 14: ...xii xii 1 2 3 SECTION REFRIGERATOR ...

Страница 15: ...1 SECTION FREEZER ...

Страница 16: ...2 SECTION FREEZER xiv ...

Страница 17: ...xv 3 SECTION FREEZER ...

Страница 18: ......

Страница 19: ...110 Woodcrest Road Cherry Hill NJ 08003 Phone 856 428 4200 Fax 856 428 7299 Website www victory refrig com E Mail parts victory refrig com order entry victory refrig com service victory refrig com ...