Troubleshooting - Fault Codes
E1
= Built-in sensor short-circuit or disconnected.
Note: The floor sensor resistance should be in the
E2
= Floor sensor damaged/disconnected/clamped on
range
of 10K Ohms - please check.
to insulation or incorrect floor sensor installed.
Dimensions
Advanced Settings
Note: These are normally set by the installer.
In ‘on’ mode, press
◯
to enter setting.
Press
△
or
▽
to select setup.
Press
◯
to enter advanced setting.
Each parameter can be accessed by pressing
◯
and
then adjust the values as required.
No
Name
Default
Ranges
1
Temp calibration - Floor sensor
-
Room sensor
0°C
0°C
-5°C to +5°C
-5°C to +5°C
2
Frost protection
Frost protection temperature
ON
5°C
OFF/ON
-5°C to +15°C
3
Sensor selection
Floor
Sensor
Room air sensor
/
Floor sensor
/
Both sensors
4
Floor temperature limit
30°C
20°C to 50°C
5
Temperature unit
°C
°C
/
°F
6
Output delay
0S
0S
/
30S
/
60S
/
90S
7
Temperature tolerance
1°C
0.5°C/1°C
/
2°C
/
3°C
8
Brightness
80%
0% - 100%
9
Energy use power rating3500W
0W
0W
–
3500W
10
Schedule
5+1+1
7/5+1+1
11
Adaptive Function
OFF
OFF
/
ON
12
Factory Reset
Back
Yes/Back
Press
◯
twice to return to normal screen or allow to time out at any time and your settings will be saved.