Important directions for fire-precaution and safety regulations.
The appliance is not designed to be used by children and persons with limited physical, sensuous and mental abilities, or by
people with not enough experience and knowledge, except in cases when they are watched and instructed how to work
with this type of heater, by someone who is responsible for their own safety.
The door of the firebox should always be firmly closed even when the appliance is not working.
The appliance should be installed only on a non-combustible floor.
The appliance and the flue pipes should be at least 80 cm away from combustible objects or constructions.
Using easily inflammable liquids is not allowed at ignition.
Vertical connection of flue pipes with the chimney through floor structures is not allowed.
The presence of easily inflammable and explosive substances in the heated room is not allowed.
The ash disposal and the cleaning of the appliance should be done only at safe places and when the appliance has cooled
down.
The appliance is intended to local heating of chambers with normal fire hazard.
It is prohibited to put combustible materials and objects on the appliance or in immediate proximity of it.
The design, connection and servicing of the water heating installation should be obligatory made by an authorized
organization.
Please pay attention during the operation of the appliance children to be kept away from it, because its surface is too hot.
Incineration
danger!
We recommend the following instructions in case of a chimney fire:
Close the combustion air regulator!
Call the fire brigade in your region!
Do not try to extinguish the fire with water by yourself!
Take away all easily inflammable materials from the chimney!
When the appliance is set to work again it is necessary the chimney to be checked by a competent person for eventual
damages.
When the appliance has been overworked over the limited heat output or for a longer period and also when using fuels
other than the recommended by the manufacturer, then we cannot guarantee reliable work of the appliance.
Please do regularly with the help of a specialist a full check of the appliance regarding its functionality. If necessary, replace
the defected parts only with the spare parts manufactured and supplied by the manufacturer.
The design and the connection of the water heating installation should be obligatory made by an authorized organization!
The installation should conform to all European and national legal documents in reference with the operation and safety!
At “open” water heating system
the installation should be connected to the atmosphere with an opened expansion
container, mounted above the highest heating device. Between the appliance and the expansion container not any blocking
components should be connected.
At “closed” water heating system
safety components should be integrated into the installation, which does not allow exceeding of the
working pressure in the appliance over 2 bar.
Do not make any non-authorized changes into construction of the appliance!
5. Cleaning.
The correct maintenance and cleaning of the appliance guarantee its reliable work and keeping its good appearance.
The flue pipes and the interior of the appliance should be cleaned at least once per year.
The painted surfaces should be cleaned with a dry and soft brush, or with dry and soft towel.
The side and top plates of the integral boiler should be cleaned once a month.
The glass should be cleaned after cooling down by washing with a soap solution and should be dried afterwards.
While cleaning do not use sharp objects or abrasive materials!
6.
Possible defects and their causes.
At ignition the appliance is smoking (not enough flue draught pressure):
The chimney and the flue pipes are not sealed;
The chimney is with wrong size;
An open doors of another appliance connected to the same chimney;
The room cannot be heated:
Bigger heat is needed;
Bad fuel;
There is a lot of ash on the bottom grate;
The air supply is not enough.
The appliance releases too much heat:
The air supply is too much;
The flue draught is really high;
The fuel is too much or the fuel is very calorific.