Victoria Atlant C Скачать руководство пользователя страница 6

Victoria-05 Ltd.

 

 

 

 

4.

 

Important directions for fire-precaution and safety regulations. 

 

The appliance is not designed to be used by children and persons with limited physical, sensuous and mental abilities, or by 
people with not  enough experience and knowledge, except  in cases when they are watched and instructed how to work 
with this type of heater, by someone who is responsible for their own safety. 

 

The door of the firebox should always be firmly closed even when the appliance is not working. 

 

The appliance should be installed only on a non-combustible floor. 

 

The appliance and the flue pipes should be at least 80 cm away from combustible objects or constructions. 

 

Using easily inflammable liquids is not allowed at ignition. 

 

Vertical connection of flue pipes with the chimney through floor structures is not allowed. 

 

The presence of easily inflammable and explosive substances in the heated room is not allowed. 

 

The  ash  disposal  and  the  cleaning  of  the  appliance  should  be  done  only  at  safe  places  and  when  the  appliance  has  cooled 
down. 

 

The appliance is intended to local heating of chambers with normal fire hazard. 

 

It is prohibited to put combustible materials and objects on the appliance or in immediate proximity of it.   

 

The  design,  connection  and  servicing  of  the  water  heating  installation  should  be  obligatory  made  by  an  authorized 
organization. 

Please pay attention during the operation of the appliance children to be kept away from it, because its surface is too hot. 

Incineration 

danger!

 

We recommend the following instructions in case of a chimney fire: 

 

Close the combustion air regulator! 

 

Call the fire brigade in your region! 

 

Do not try to extinguish the fire with water by yourself! 

 

Take away all easily inflammable materials from the chimney! 

 

When  the  appliance  is  set  to  work  again  it  is  necessary  the  chimney  to  be  checked  by  a  competent  person  for  eventual 
damages. 

When the appliance has been overworked over the limited heat  output  or for a longer period and also  when using fuels 
other than the recommended by the manufacturer, then we cannot guarantee reliable work of the appliance. 

Please do regularly with the help of a specialist a full check of the appliance regarding its functionality. If necessary, replace 

the defected parts only with the spare parts manufactured and supplied by the manufacturer. 

The design and the connection of the water heating installation should be obligatory made by an authorized organization! 
The installation should conform to all European and national legal documents in reference with the operation and safety! 

At  “open”  water  heating  system

  the  installation  should  be  connected  to  the  atmosphere  with  an  opened  expansion 

container,  mounted  above  the  highest  heating  device.  Between  the  appliance  and  the  expansion  container  not  any  blocking 
components should be connected.

 

At “closed” water heating system

 safety components should be integrated into the installation, which does not allow exceeding of the 

working pressure in the appliance over 2 bar. 

Do not make any non-authorized changes into construction of the appliance! 

5. Cleaning. 

The correct maintenance and cleaning of the appliance guarantee its reliable work and keeping its good appearance. 
The flue pipes and the interior of the appliance should be cleaned at least once per year. 
The painted surfaces should be cleaned with a dry and soft brush, or with dry and soft towel. 

The side and top plates of the integral boiler should be cleaned once a month. 
The glass should be cleaned after cooling down by washing with a soap solution and should be dried afterwards. 

While cleaning do not use sharp objects or abrasive materials! 

 
6.

 

Possible defects and their causes. 

At ignition the appliance is smoking (not enough flue draught pressure): 

 

The chimney and the flue pipes are not sealed; 

 

The chimney is with wrong size; 

 

An open doors of another appliance connected to the same chimney; 

The room cannot be heated: 

 

Bigger heat is needed; 

 

Bad fuel; 

 

There is a lot of ash on the bottom grate; 

 

The air supply is not enough. 

The appliance releases too much heat: 

 

The air supply is too much; 

 

The flue draught is really high; 

 

The fuel is too much or the fuel is very calorific. 

Содержание Atlant C

Страница 1: ...INSTRUCTION MANUAL for installation and operation of wood burning stoves and fireplaces...

Страница 2: ...ENTS 1 Introduction 3 2 Appliance assembling 3 3 Appliance operation 4 4 Important instructions for fire precaution and safety regulations 6 5 Cleaning 6 6 Possible defects and their causes 6 7 Append...

Страница 3: ...can be connected to the same chimney The flue draught should be higher than 10 Pa but for stoves with a boiler up to 15 Pa If the chimney is too high the draught exceeding 35 Pa then it is necessary...

Страница 4: ...ocess As a result of too high temperatures or mechanical influences the refractory plates might be damaged Extremely high temperatures may be achieved when with high flue draught of the chimney the pr...

Страница 5: ...th soot In addition there are harmful emissions which may cause burning in the chimney As the heat output of your appliance depends on the height of the chimney the precise control of the necessary ai...

Страница 6: ...when using fuels other than the recommended by the manufacturer then we cannot guarantee reliable work of the appliance Please do regularly with the help of a specialist a full check of the appliance...

Страница 7: ...5 11 79 62 7 56 217 12 30 25 100 2 2 38 530 507 1140 181 Marinela PBO t 3 27 5 11 79 62 7 56 217 12 30 25 100 2 2 38 550 507 1140 194 Marinela PSBO t 3 27 5 11 79 62 7 56 217 12 30 25 100 2 2 38 530 5...

Страница 8: ...58 12 30 35 80 2 21 510 418 900 75 Maestro K 7 52 76 94 6 32 258 12 30 35 80 2 21 470 400 960 85 Tali 7 52 76 94 6 32 258 12 30 35 80 2 21 510 418 900 81 Triton 7 52 76 94 6 32 258 12 30 35 80 2 21 51...

Страница 9: ...53 Bora L 5 00 80 01 4 88 223 12 50 50 80 1 48 364 355 700 47 Bora Lux L 5 00 80 01 4 88 223 12 50 50 80 1 48 364 365 626 46 Deluxe Sl 5 00 80 01 4 88 223 12 50 50 80 1 48 380 372 700 43 Nero 6 00 80...

Страница 10: ...e integral boiler in the lowest point drains tap not less than should be mounted All components of the installation should be ensured against freezing especially if the expansion container or other pa...

Страница 11: ...ing group up to 1 5 bar 16 Entry from water conduit 17 Filter 18 Pump 19 Non return valve 20 Turn cock for filling and draining the system 21 Expander tank INSTALLATION DIAGRAM for connecting of wood...

Страница 12: ...Victoria 05 Ltd 61A Anton Strashimirov Str 5100 Gorna Oryahovitsa Republic of Bulgaria phone 359 618 60282 fax 359 618 60200 e mail info v05 bg http www v05 bg...