Closed expansion tank
Absorbs the differences in the volume of the water caused by the heating.
Technician has to decide is it needed to add second tank to the existing one, depending from the volume of
the water in the system.
Venting valve (deaerator)
Positioned on the top part, allowing to bleed the system from any air inside, present during filling with water.
Picture.3
10.Installation:
Warning!
Installation of the stove and the heating system should be made by authorized and licensed organization!
The manufacture of the stove does not guarantee the proper working of the installation. The guarantee is
only for the stove.
Any maintains, check-ups and work on the electrical components should be made only by authorized
personal. Before any work on the stove disconnect from the electric supply
.
Refer to any local regulations valid for your country if you don’t find the required information in this
instruction manual.
It is forbidden to install the stove in bedrooms, bathrooms and in rooms in which there is already installed
another heating appliance. If there is already installed heating appliance, it has to be with separate air supply.
Verify compatibility with other devices.
The stove must not be installed in the same room in which are installed air extractors types A and B, gas
appliances or any devices which are reducing the ventilation in the room.
Check all electrical connections. The electric socket should be positioned in easy to reach and access place.
The stove is equipped with electric cable to be connected to a 230V 50Hz socket. Any variations in the voltage
above 10% can cause malfunction in the appliance (unless the appropriate differential switch is installed). The
electrical system should be in accordance with all local regulations and laws, especially regarding the earthing.
In accordance with the regulations for connecting to the electrical system, the stove should be mounted in a
proper way which can guarantee easy access to electric socket (230V 50Hz). It is forbidden to install the stove
in rooms where the electrical system is on the floor.
Any lack of efficiency in the electrical system or “ground” circuit can cause malfunction for which the producer
cannot be held responsible.
Positioning:
The stove must be leveled when installed. The floor must be even, horizontal and made by fireproof materials.
If the floor is not fireproof (carpet for example) there must be used fireproof base made by steel, glass or
stone plates.
Safety distances for fire preventing:
The stove must be installed in accordance with the following safety requirements:
-
Medium flammable items must be kept in distance minimum 40 cm. from the back and the sides of the
stove.
-
Easily flammable items must be kept in distance minimum 80 cm. in front of the stove.
- If the stove is mounted on easy flammable floor, there must be placed a sheet of heat insulation under
the stove. It must be extended above the base of the stove with more than 20 cm at the sides and more than
40 cm in front.
Flammable objects must not be placed above the stove or at a distance that is any less than the above
mentioned safety distances. If connected to wooden walls or other flammable materials, the smoke exhaust
pipe must be appropriately insulated with ceramic fibre or other similar material.
Air inlet:
Warning! Incoming air must be ensured.