The pellet stove is equipped with system which ensures optimal burning.  
 

The  system  ensures  excellent  operation  thanks  to  two  sensors  measuring  the  pressure  level  in  the 
combustion chamber and smoke temperature. The  detection of  and  subsequent optimisation of  these two 
parameters is continuous in order to correct opera- tion anomalies in real time

.

 

 

The system offers constant combustion, automatically regulating the draft based on the characteristics of the 
chim-  ney  flue  (bends,  length,  shape,  diameter,  etc..)  and  environmental  conditions  (wind,  humidity, 
atmospheric pressure, installations at high altitude, etc.). The standards for installation must be respected.

 

 

The system is also able to recognise the type of pellets and automatically adjust the flow moment by moment to 
ensure the required level of combustion (use wood pellets with a diameter of approximately 6 mm).

 

6.Principle of operation: 

             

                    

 

                                

Picture 2

                                                                

Picture 2.1

 

The  stove  is  fuelled  by  pellets.  These  are  little,  cylindrical  shapes  of  pressed  wood  whose  combustion  is 
controlled  electronically.  The  heat  produced  by  combustion  is  mainly  transmitted  to  the  water  and  partly 
emitted into the room by radiation

The fuel tank - hopper (А) is located at the back of the stove. Loading the tank is thru the back of the lid at the 
rear  of  the  top.  The  fuel  (pellets)  is  taken  from  the  tank  (A)  and  via  an  Archimedes  screw  (В)  powered  by 
electric gear motor (С) is transported to the combustion chamber (D). 
The  ignition of  the pellets as made  by air, heated by electrical heating element  (Е)  which is sucked into the 
combustion chamber by the smoke extractor (F). 

The combustion air is drawn into the room (where there must be an air intake) smoke extractor

 (F). 

 

The smoke produced by combustion, is extracted from the stove through the smoke extractor

 (F) 

and expelled 

from the pipe union

 

located in the bottom part of the rear of the stove

The  ash  falls  under  and  beside  the  crucible  in  which  is  housed  an  ash  tray  from  which  the  ash  must  be 
periodically removed by vacuuming when cool.

 

The hot water produced by the stove is transferred by circulation pump build in the stove to the system.  
Filling and empting of the system is made by build in valve and control manometer Picture.2.1. 
The stove is

 designed to function with closed expansion tank 

(Н) 

and pressure valve, both of which are built in

Fuel  quantity,  smoke  extraction/combustion  air  supply  and  pump  activation  are  regulated  by  the  control 
board

which is equipped with software to achieve high combustion efficiency and low emissions

. The control 

panel  (G)  is  placed on  the  top of  the  stove  and  can control,  check  and  see  all phases  from  the  work of  the 
stove. 

 

 

 

C

G

A

F

D

E

Содержание Vittoria B Series

Страница 1: ...1 Instruction for installation and operation of pellet burning stove with integral water boiler VITTORIA...

Страница 2: ...nciple of operation 7 7 Operation 8 8 Safety and detection devices 8 9 Components 8 10 Installation 9 11 Basic instructions for use 11 12 Instructions for use 12 13 Operating modes 12 14 Maintenance 1...

Страница 3: ...can be damaged if it is ignited or used with no water in the system The stove is designed to heat water by means of automatic combustion of pellets wood with 6 mm diameter in the combustion chamber If...

Страница 4: ...tly and safely The stove must be kept in a room where the temperature is above 0 C Use appropriate anti freeze additives for the water of the system Ensure that the temperature of the return water is...

Страница 5: ...s are calculated on the basis of pellets with an heating value of at least 4300 kcal kg and heating loss of the roomof 33 Kcal m h It is also important to consider the position of the stove in the roo...

Страница 6: ...has to be reset manually Tank safety thermostat Switches off when the temperature in the stove is too high It stops pellet loading which is causing the stove to shut down It has to be reset manually...

Страница 7: ...ing the tank is thru the back of the lid at the rear of the top The fuel pellets is taken from the tank A and via an Archimedes screw powered by electric gear motor is transported to the combustion ch...

Страница 8: ...mocouple It is located at the smoke exhaust to measure the temperature It is also controlling the ignition and if the temperature is too high or too low it triggers shut down sequence Stop Flame Hoppe...

Страница 9: ...ations in the voltage above 10 can cause malfunction in the appliance unless the appropriate differential switch is installed The electrical system should be in accordance with all local regulations a...

Страница 10: ...d into a chimney flue a vertical section of at least 1 5 m will be required complete with a wind guard The vertical duct can be internal or external If the smoke channel is outside it must be insulate...

Страница 11: ...ring the filling bleed the pump manually and open the manual vent Picture 3 These actions must be carried subsequently periodically 11 Basic instructions for use Command board Picture 5 1 Button turn...

Страница 12: ...date set 12 Instructions for use Feeling the feed screw When the tank for pellets is completely empty this means that the feed screw is also empty Before re igniting the stove you must fill it up fol...

Страница 13: ...on the display if is pressed No Prog Prog No 1 one ignition and shutdown per day Prog No2 same as before Prog No3 same as before Use the button to show them in reverse order If you choose the first pr...

Страница 14: ...not performed and at least once a season don t make a complete cleaning could cause to poor functionality Any problems resulting from lack of maintenance will immediately void the warranty Daily maint...

Страница 15: ...own If the procedures for maintenance are not performed regularly the warranty will void If the stove is used very often it is recommended to clean the smoke channel once every 3 months Warning After...

Страница 16: ...rift 8 H2O TEMPALARM Shuts down due to water temperature being higher than 90 C An excessive temperature may occur because of the following system too small ask the DEALER to activate the ECO function...

Страница 17: ...stove produce hot air NO Most of the heat is transferred by the water Only small part of the heat is transferred to the room whre the stove is installed by means of radiant heat from the glass It is r...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...not kept damages caused during transport inappropriate made heating calculations and project for heating system and installation of the stove there have been made changes in the construction of the st...

Страница 21: ...21 Victoria 05 Ltd 61A Anton Strashimirov Str 5100 Gorna Oryahovitsa Bulgaria phone 359 618 60282 fax 359 618 60200 e mail info v05 bg...