4.Safety devices: 

-Thermocouple: 
Placed at the smoke outlet to detect temperature. Turns the stove on and off and also controls its operation based 
on defined parameters.  
-Vacuum gauge: (electronic pressure sensor) 
Placed  on  the  smoke  extractor  which  detects  the  vacuum  value  (compared  to  the  installation  enviroment)  in  the 
combustion chamber 
-Safety thermostat: 
Switches off when the temperature in the stove is too high.  
It stops pellet loading which is causing the stove to shut down. It has to be reset manually.  
-Tank safety thermostat: 
Switches off when the temperature in the stove is too high.  
It stops pellet loading which is causing the stove to shut down. It has to be reset manually. 
-Fuse:   
At the back of the stove are placed 2 fuses. One in the button with socket and one for spare.   

5.Electronic circuit board: 

 

Scheme 1 

1.smoke extraction motor control  
2.inlet air sensor 
3.thermoregulator exit water 
4.vacuum gauge 
5.outlet air sensor  
6.power supply 
7.ignition unit 

  8.sensor  tº hopper housing 
  9.thermal limiter tº outlet water 

             10.hopper 
             11.pump 
             12.smoke extraction motor 

13.electric wire - black 
14.electric wire - black 
15.electric wire - brown 
16.control panel 
17.socket 

Содержание Vittoria B Series

Страница 1: ...1 Instruction for installation and operation of pellet burning stove with integral water boiler VITTORIA...

Страница 2: ...nciple of operation 7 7 Operation 8 8 Safety and detection devices 8 9 Components 8 10 Installation 9 11 Basic instructions for use 11 12 Instructions for use 12 13 Operating modes 12 14 Maintenance 1...

Страница 3: ...can be damaged if it is ignited or used with no water in the system The stove is designed to heat water by means of automatic combustion of pellets wood with 6 mm diameter in the combustion chamber If...

Страница 4: ...tly and safely The stove must be kept in a room where the temperature is above 0 C Use appropriate anti freeze additives for the water of the system Ensure that the temperature of the return water is...

Страница 5: ...s are calculated on the basis of pellets with an heating value of at least 4300 kcal kg and heating loss of the roomof 33 Kcal m h It is also important to consider the position of the stove in the roo...

Страница 6: ...has to be reset manually Tank safety thermostat Switches off when the temperature in the stove is too high It stops pellet loading which is causing the stove to shut down It has to be reset manually...

Страница 7: ...ing the tank is thru the back of the lid at the rear of the top The fuel pellets is taken from the tank A and via an Archimedes screw powered by electric gear motor is transported to the combustion ch...

Страница 8: ...mocouple It is located at the smoke exhaust to measure the temperature It is also controlling the ignition and if the temperature is too high or too low it triggers shut down sequence Stop Flame Hoppe...

Страница 9: ...ations in the voltage above 10 can cause malfunction in the appliance unless the appropriate differential switch is installed The electrical system should be in accordance with all local regulations a...

Страница 10: ...d into a chimney flue a vertical section of at least 1 5 m will be required complete with a wind guard The vertical duct can be internal or external If the smoke channel is outside it must be insulate...

Страница 11: ...ring the filling bleed the pump manually and open the manual vent Picture 3 These actions must be carried subsequently periodically 11 Basic instructions for use Command board Picture 5 1 Button turn...

Страница 12: ...date set 12 Instructions for use Feeling the feed screw When the tank for pellets is completely empty this means that the feed screw is also empty Before re igniting the stove you must fill it up fol...

Страница 13: ...on the display if is pressed No Prog Prog No 1 one ignition and shutdown per day Prog No2 same as before Prog No3 same as before Use the button to show them in reverse order If you choose the first pr...

Страница 14: ...not performed and at least once a season don t make a complete cleaning could cause to poor functionality Any problems resulting from lack of maintenance will immediately void the warranty Daily maint...

Страница 15: ...own If the procedures for maintenance are not performed regularly the warranty will void If the stove is used very often it is recommended to clean the smoke channel once every 3 months Warning After...

Страница 16: ...rift 8 H2O TEMPALARM Shuts down due to water temperature being higher than 90 C An excessive temperature may occur because of the following system too small ask the DEALER to activate the ECO function...

Страница 17: ...stove produce hot air NO Most of the heat is transferred by the water Only small part of the heat is transferred to the room whre the stove is installed by means of radiant heat from the glass It is r...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...not kept damages caused during transport inappropriate made heating calculations and project for heating system and installation of the stove there have been made changes in the construction of the st...

Страница 21: ...21 Victoria 05 Ltd 61A Anton Strashimirov Str 5100 Gorna Oryahovitsa Bulgaria phone 359 618 60282 fax 359 618 60200 e mail info v05 bg...