background image

- 8 -

Table

Table

Table

Table

2-4.Pushbutton

2-4.Pushbutton

2-4.Pushbutton

2-4.Pushbutton

Using

Using

Using

Using

Hold

Hold

Hold

Hold

Mode

Mode

Mode

Mode

In the measuring mode, use

to select Display Hold, Auto Hold or Peak Hold. Press again to exit.

START

START

START

START

HOLD

HOLD

HOLD

HOLD

The above three functions are not available when recording data.

Display

Display

Display

Display

Hold

Hold

Hold

Hold

Mode

Mode

Mode

Mode

(D.H)

(D.H)

(D.H)

(D.H)

The primary display preserves the present value, and displays “

(

see Figure 2-6)

.

Figure 2-6. D.H Mode

In MAX, MIN mode, no further minimum, maximum, or average updates occur while the HOLD mode is enabled.

Pushbutton

Pushbutton

Pushbutton

Pushbutton

Description

Description

Description

Description

Yellow

Yellow

Yellow

Yellow

Button

Button

Button

Button

Function

Function

Function

Function

Description

Description

Description

Description

Note

Press

to access “Yellow Button Functions”, and

will be on display

Press to access blue functions on the rotary switch.
In Setup and Comparative Mode, use arrow

function(

) function to select the next digit

(None)

START

START

START

START

HOLD

HOLD

HOLD

HOLD

In measuring mode,

selects between the D.H, A.H and

P.H functions. To cancel functions, press this key once
again.

In Logging mode or Comparative mode, press

to start storage function.

START

START

START

START

HOLD

HOLD

HOLD

HOLD

(None)

In measuring mode, press

to exit

auto-ranging

and enter manual ranging. In manual, select next
input range.
In Comparative mode

press

to set MAX and

MIN value.
Press

to enter Setup mode when turning the

meter on

and press

to select the set value in

the mode.

(None)

In measuring mode, press

to store the present

reading as an offset reference; subsequent readings
show only the relative difference from this value.
In MEM mode

press

to read the Save Data.

Enter SAVE mode.
In SAVE mode, press

to save

present value. Press for more than 2
seconds to exit.

In Setup or comparative mode, increment a digit.
In MEM mode to read the display value

press

to get the previous record.

In measuring mode

press

to

return to AUTO ranging.

In measuring mode, successively press

to

select frequency, duty cycle ratio, and voltage
(current) in Voltage and Current position(except
DC mV function)
In MEM mode, press

to read LOGGING Data.

Enter LOG mode.
Press for more than 2 seconds to exit.

In measuring mode, press

to start retaining

min, max, and average values.
Press successively to display MAX, MIN, and
AVG value.
Press for more than 2 seconds to stop.
In MEM

press to read COMP Data.

Enter SAVE mode.
Press for more than 2 seconds to exit.

In Setup or COMP mode, decrement a digit.
In MEM mode

press to get the next data stored

otherwise to clear off the data if pressing for more
than 2 seconds

None

Turn on the power or backlight.
Press for less than 2 seconds to turn on or off the
backlight and more than 2 seconds to power off.

None

Содержание 98A

Страница 1: ...d on on on the the the meter meter meter between between between terminals terminals terminals or or or between between between any any any terminal terminal terminal and and and earth earth earth gro...

Страница 2: ...seconds seconds and and and then then then restart restart restart the the the meter meter meter Automatic Automatic Automatic Power Power Power Off Off Off The meter will go into automatic power off...

Страница 3: ...how the pushbutton function Figure Figure Figure 2 1 O 2 1 O 2 1 Outer uter uter Structure Structure Structure Figure Figure Figure 2 2 Input 2 2 Input 2 2 Input Jacks Jacks Jacks Table Table Table 2...

Страница 4: ...button Function Function Function AC Voltage Measurement dBm Measurement DC Voltage Measurement None DC mA Voltage Measurement TC Measurement Resistance Measurement Diode testing continuity testing RT...

Страница 5: ...ent primary display shows MIN MAX AVG value in cycle while secondary display shows present reading Low battery indicator The indicator in the display notifies you that the batteries are low and should...

Страница 6: ...elow 1 mW dBm AC AC AC DC DC DC Alternating current direct current Display the duty cycle ratio of signals when measuring frequency Bar Graph The polarity indicator both ends of the bar graph show the...

Страница 7: ...7...

Страница 8: ...and enter manual ranging In manual select next input range In Comparative mode press to set MAX and MIN value Press to enter Setup mode when turning the meter on and press to select the set value in t...

Страница 9: ...A H A H Note Note Note Peak Peak Peak HOLD HOLD HOLD mode mode mode is is is only only only available available available in in in DCV DCV DCV In Peak HOLD mode the meter detects refresh and displays...

Страница 10: ...e Mode Mode Note The function is invalid in REL TC RTD dBm DC mV Diodes Continuity Capacitance Frequency Duty cycle ratio features The MIN MAX mode stores minimum MIN and maximum MAX input values MIN...

Страница 11: ...ge Voltage is the difference in electrical potential between two points The polarity of ac alternating current voltage varies over time while the polarity of direct current voltage is constant over ti...

Страница 12: ...easurements with the following procedure 1 Make an ac volt measurement to be used as a reference point 2 Press to select dB The dBm value appears in the primary display and the ac volts reading appear...

Страница 13: ...ps beeps beeps constantly constantly constantly if if if the the the input input input voltage voltage voltage is is is more more more than than than AC AC AC 750V 750V 750V rms rms rms which which wh...

Страница 14: ...ead lead can can can add add add 0 1 0 1 0 1 to to to 0 2 0 2 0 2 of of of error error error to to to resistance resistance resistance measurements measurements measurements To To To test test test th...

Страница 15: ...st test test disconnect disconnect disconnect circuit circuit circuit power power power and and and discharge discharge discharge all all all high voltage high voltage high voltage capacitors capacito...

Страница 16: ...the the the red red red lead lead lead with with with the the the positive positive positive point point point and and and the the the black black black lead lead lead with with with the the the nega...

Страница 17: ...nce to select alternating current measurement and the screen shows AC 4 Open the circuit path to be tested Touch the red probe to the more positive side of the break touch the black probe to the more...

Страница 18: ...atio and then back to voltage current Frequency Duty cycle ratio Voltage Current Voltage Current Frequency Frequency Duty cycle ratio Figure3 13 Frequency Figure3 13 Frequency Figure3 13 Frequency and...

Страница 19: ...ng time and interval time of the real time data see Changing the Default Settings 2 Press LOG LOG LOG appears on the screen and the recorded number appears in the secondary display the elapsed time di...

Страница 20: ...MEM MEM MEM position position position Notice Notice Notice In In In MEM MEM MEM function function function each each each operation operation operation could could could only only only read read read...

Страница 21: ...any dirt that may be in the terminals 3 Soak a new swab with alcohol Work the swab around in each terminal Testing Testing Testing the the the Fuses Fuses Fuses Warning Warning Warning To To To avoid...

Страница 22: ...er needs four AAA alkaline batteries Warning Warning Warning To To To avoid avoid avoid electrical electrical electrical shock shock shock Remove Remove Remove test test test leads leads leads from fr...

Страница 23: ...Pollution Degree 2 Safety Standard issued by IEC Fuse Fuse Fuse Protection Protection Protection for for for mA mA mA or or or A A A inputs inputs inputs Fuse Fuse Fuse Protection Protection Protectio...

Страница 24: ...esolution Resolution Accuracy Accuracy Accuracy 40 400Hz Remark Remark Remark 400 0 mV 0 1 mV 1 0 4 Specifications are valid from 5 to 100 of amplitude range 400mV is only confined to manual range AC...

Страница 25: ...5 4 4 000A 0 001A 1 4 Measuring Impedance 0 01 Overvoltage 10A 250V fast blow fuse 10 00A 0 01A 1 4 Range Range Range Frequency Frequency Frequency Accuracy Remark 400 0 0 1 0 2 4 Open circuit voltag...

Страница 26: ...rounds to apply this product to a particular purpose K 200 to 950 1 0 5 2 100 0 5 1 100 By using ITS 90 temperature scale Note The accuracy does not include the error of internal temperature compensat...

Отзывы: