- 8 -
Table
Table
Table
Table
2-4.Pushbutton
2-4.Pushbutton
2-4.Pushbutton
2-4.Pushbutton
Using
Using
Using
Using
Hold
Hold
Hold
Hold
Mode
Mode
Mode
Mode
In the measuring mode, use
to select Display Hold, Auto Hold or Peak Hold. Press again to exit.
START
START
START
START
HOLD
HOLD
HOLD
HOLD
The above three functions are not available when recording data.
Display
Display
Display
Display
Hold
Hold
Hold
Hold
Mode
Mode
Mode
Mode
(D.H)
(D.H)
(D.H)
(D.H)
The primary display preserves the present value, and displays “
”
(
see Figure 2-6)
.
Figure 2-6. D.H Mode
In MAX, MIN mode, no further minimum, maximum, or average updates occur while the HOLD mode is enabled.
Pushbutton
Pushbutton
Pushbutton
Pushbutton
Description
Description
Description
Description
Yellow
Yellow
Yellow
Yellow
Button
Button
Button
Button
Function
Function
Function
Function
Description
Description
Description
Description
Note
Press
to access “Yellow Button Functions”, and
will be on display
○
Press to access blue functions on the rotary switch.
In Setup and Comparative Mode, use arrow
function(
) function to select the next digit
(None)
START
START
START
START
HOLD
HOLD
HOLD
HOLD
In measuring mode,
selects between the D.H, A.H and
P.H functions. To cancel functions, press this key once
again.
In Logging mode or Comparative mode, press
to start storage function.
START
START
START
START
HOLD
HOLD
HOLD
HOLD
(None)
In measuring mode, press
to exit
auto-ranging
and enter manual ranging. In manual, select next
input range.
In Comparative mode
,
press
to set MAX and
MIN value.
Press
to enter Setup mode when turning the
meter on
,
and press
to select the set value in
the mode.
(None)
In measuring mode, press
to store the present
reading as an offset reference; subsequent readings
show only the relative difference from this value.
In MEM mode
,
press
to read the Save Data.
Enter SAVE mode.
In SAVE mode, press
to save
present value. Press for more than 2
seconds to exit.
In Setup or comparative mode, increment a digit.
In MEM mode to read the display value
,
press
to get the previous record.
In measuring mode
,
press
to
return to AUTO ranging.
In measuring mode, successively press
to
select frequency, duty cycle ratio, and voltage
(current) in Voltage and Current position(except
DC mV function)
In MEM mode, press
to read LOGGING Data.
Enter LOG mode.
Press for more than 2 seconds to exit.
In measuring mode, press
to start retaining
min, max, and average values.
Press successively to display MAX, MIN, and
AVG value.
Press for more than 2 seconds to stop.
In MEM
,
press to read COMP Data.
Enter SAVE mode.
Press for more than 2 seconds to exit.
In Setup or COMP mode, decrement a digit.
In MEM mode
,
press to get the next data stored
otherwise to clear off the data if pressing for more
than 2 seconds
(
None
)
Turn on the power or backlight.
Press for less than 2 seconds to turn on or off the
backlight and more than 2 seconds to power off.
(
None
)