Chapter 4 shows you how to use memory and communication features available on the meters.
Data
Data
Data
Data
Storage
Storage
Storage
Storage
The meter has three types of memory data: SAVE mode, LOG mode and COMP mode.
Notice
Notice
Notice
Notice
Undertake “clearing memory data” operation first if the date storage functions are used firstly.
The date storage mode is unavailable when the meter is in D.H, A.H, P.H, Hz% or MAX MIN function. The COMP mode is
unavailable when measuring capacitance. The range cannot be changed when the date storage functions are active.
In MEM position, “- - - -”on the screen indicates data storage is empty and could save the data; “FULL” on the screen
indicates data storage is full and will stop saving.
In LOG or COMP mode, no data could be saved if there is a recording (no matter the storage is full or not).
The user should clear off the memory and then start to save. In LOG or COMP mode, the meter will return to measuring
mode when the storage is full.
Low battery indicator
Appears on the screen to indicating forbid saving.
Table
Table
Table
Table
4-1.
4-1.
4-1.
4-1.
Memory
Memory
Memory
Memory
Capacity
Capacity
Capacity
Capacity
SAVE
SAVE
SAVE
SAVE
Mode
Mode
Mode
Mode
Proceed as follows:
1.
Press
to save reading, “
MEM
MEM
MEM
MEM
” appears in the display and record number is displayed in the secondary display, the
meter enters into SAVE mode.
2.
Press
to save present value in the memory and the record number increments by one.
3.
Press
for more than 2S o
r set the rotary switch to any other position to exit the SAVE mode.
LOG
LOG
LOG
LOG
Mode
Mode
Mode
Mode
Proceed as follows:
1.
Set the starting time and interval time of the real time data (see “Changing the Default Settings”).
2.
Press
, “
LOG
LOG
LOG
LOG
” appears on the screen and the recorded number appears in the secondary display; the elapsed time
display shows the time and the meter enters into LOG mode.
3.
Press
to start log mode, and counts the time. On the starting time, the meter begins to store the data in the Logging
Saving Memory. The meter exits the mode automatically when the storage is full.
4.
Press
for more than 2S or change the rotary switch position to exit the mode.
COMP
COMP
COMP
COMP
Mode
Mode
Mode
Mode
1.
Press
, “
COMP
COMP
COMP
COMP
” appears on the screen and the record number appears in the secondary display; the elapsed time
display shows the time and the meter enters into COMP mode.
2.
Set the upper and lower limits. Press
to set the upper limit and “
MAX
MAX
MAX
MAX
” appears on the screen, and the digit set part in
the primary display flashes. Press the blue button to select the set digits. Use
or
to change the numerical value of the
set digits. Press
again to set the lower limit and “MIN” displays. The setting way of the lower limit is same as that of the
upper limit. Press for the third time to save the set data.
3.
Press
to start COMP mode. If you do not undertake step 2, then the default values of the upper and lower limits are
zero. Pressing
is invalid when setting the upper and lower limit values.
Viewing
Viewing
Viewing
Viewing
Memory
Memory
Memory
Memory
Data
Data
Data
Data
Use the following procedure to view memory data:
1.
Disconnect the input leads at the measurement source.
Warning
Warning
Warning
Warning
To
To
To
To
avoid
avoid
avoid
avoid
electric
electric
electric
electric
shock,
shock,
shock,
shock,
disconnect
disconnect
disconnect
disconnect
the
the
the
the
test
test
test
test
leads
leads
leads
leads
when
when
when
when
the
the
the
the
rotary
rotary
rotary
rotary
switch
switch
switch
switch
is
is
is
is
in
in
in
in
the
the
the
the
MEM
MEM
MEM
MEM
position.
position.
position.
position.
Notice
Notice
Notice
Notice
Memory Mode
Memory Capacity
SAVE mode
500
LOG mode
1000
COMP mode
1000