MAINTENANCE
DANGER
• Before performing any
maintenance on the
tool, disconnect the
power cord from the
electrical source.
Failure to follow this
instruction could result in
death or serious personal
injury.
This section provides information about keeping
the tool in proper operating condition .
Replacement parts must be ordered from
Victaulic to verify proper and safe operation of
the tool .
LUBRICATION
Once per week, lubricate the three grease
fittings on the tool body with a No . 2EP lithium-
based grease .
CLEANING THE GROOVING CUP
When grooving galvanized pipe, some flaking
of the galvanized coating may occur and lodge
inside the grooving cup .
Periodically inspect the pipe insertion area on
the front of the grooving head . If any debris is
visible inside the grooving cup, clear away the
material with a wire brush .
PARTS ORDERING
INFORMATION
When ordering parts, the following information
is required for Victaulic to process the order and
send the correct part(s) . Parts can be ordered
by calling 1-800-PICK-VIC .
1.
Tool Model Number
2.
Tool Serial Number
3.
Quantity, Item Number, Part Number, and
Description
4.
Where to send the part(s) – Company
Name and Address
5.
To whose attention to send the part(s) –
Person’s Name
6.
Purchase Order Number
7.
Billing Address
17
REV_C
TM-RG2910