background image

OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL

RG2910 Roll Grooving Tool

WARNING

Original Instructions

 

WARNING

Failure to follow instructions and warnings could result in death, 
serious personal injury, property damage, and/or product damage.
•  Before operating or servicing any grooving tools, read all 

instructions in this manual and all warning labels on the tool.

•  Wear safety glasses, hardhat, foot protection, and hearing 

 protection while working around this tool.

•  Save this operating and maintenance manual in a place 

accessible to all operators of the tool.

If you need additional copies of any literature, or if you have questions concerning the safe 
and proper operation of this tool, contact Victaulic, P.O. Box 31, Easton, PA 18044-0031, 
Phone: 1-800-PICK-VIC, E-Mail: [email protected].

REV_C

TM-RG2910

Содержание RG2910

Страница 1: ...nstructions in this manual and all warning labels on the tool Wear safety glasses hardhat foot protection and hearing protection while working around this tool Save this operating and maintenance manu...

Страница 2: ......

Страница 3: ...e Setup 10 Drive Setup 11 Tool and Carriage Assembly Setup 12 Cutting and Reaming Operation 13 Grooving Operation 14 Using the Groove Confirmation Cable 16 Maintenance 17 Lubrication 17 Cleaning the G...

Страница 4: ...IOR to work ing with the grooving tool These instructions describe safe operation of the tool including set up and maintenance Each operator must become familiar with the tool s operations application...

Страница 5: ...to the operator 8 Do not make any modifications to the tool Do not remove any safety guarding or any components that would affect tool performance CAUTION 1 RG2910 tools are designed ONLY for groovin...

Страница 6: ...that fall within the designated parameters Failure to follow these instructions could damage the tool and cause product failure resulting in property damage or personal injury RECEIVING THE TOOL RG29...

Страница 7: ...in accordance with Article 250 of the National Electrical Code and all applicable local electrical codes If an extension cord is required refer to the Extension Cord Requirements section that follows...

Страница 8: ...ntains trademarks copyrights and or patented features that are the exclusive property of Victaulic Safety Foot Switch Stand Assembly Power Drive Grooving Head Reamer Cutter Actuator Carriage Assembly...

Страница 9: ...dB A Sound measurements are taken with a Ridgid Model 300 power drive NOTE Noise measurements are dependent on the power drive and will vary based on configuration Always check the power drive manufac...

Страница 10: ...When grooving pipe from 4 5 to 6 75 inches in length leave 2 inches of pipe extended from the front of the chuck When grooving longer pipe lengths leave 2 4 5 inches of pipe extended from the front of...

Страница 11: ...Victaulic Operating the tool without a safety foot switch could result in serious personal injury 3 Turn the switch on the side of the power drive to create counterclockwise rotation as seen from the...

Страница 12: ...use store them and any applicable accessories in a clean dry area that is readily available to all operators 1 With the grooving head up in the storage position grasp the head with both hands and pull...

Страница 13: ...ious sections of this manual have been followed Read and understand the operation of the cutter and reamer by referring to the manual provided by the manufacturer s Prepare for pipe ends and cut lengt...

Страница 14: ...proceeding verify that all instructions in the previous sections of this manual have been followed NOTICE When grooving pipe from 4 5 to 6 75 inches in length leave 2 inches of pipe extended from the...

Страница 15: ...n the carriage lever to keep the tool in position during grooving Depress the safety foot switch to start the power drive then press and release the actuator NOTE Keep all other objects away from the...

Страница 16: ...ble Carefully check the groove diameter C dimension using the provided groove confirmation cable Refer to the Roll Groove Specifications section CAUTION The C dimension groove diameter must conform to...

Страница 17: ...e some flaking of the galvanized coating may occur and lodge inside the grooving cup Periodically inspect the pipe insertion area on the front of the grooving head If any debris is visible inside the...

Страница 18: ...ription 2A R059910ADP 1 Ridgid Stop Arm 2B 1 Ridgid Mounting Stud Block Assembly ROTHENBERGER ADAPTER KIT 3A 3B Item No Part No Qty Description 3A R057910ADP 1 Rothenberger Stop Arm 3B 1 Rothenberger...

Страница 19: ...s insert a flat head screwdriver into the notches that bisect the Ready to Groove Indicator Twist the screwdriver in either direction until the indicator pops into the locked position so that it no lo...

Страница 20: ...re groove Facility has lost power Upon restoration of facility power cut off pipe end and re groove Tool stalls mid cycle or will not groove after actuating Tool has reached end of life Replace tool T...

Страница 21: ...Groove Diameter C Groove Depth D ref Max Allow Wall Thick T Min Allow Wall Thick T Max Allow Flare Dia Max Min Basic Max Min Basic Max Min Max Min 1 1 327 1 346 1 300 0 375 0 405 0 345 0 150 0 160 0 1...

Страница 22: ...l documentation prepared in accordance with Annex VII B of the Machinery Directive 2006 42 EC will be made available upon request to the governing authorities Compatible Power Drives When installed wi...

Страница 23: ...ation prepared in accordance with Annex VII A of The Supply of Machinery Safety Regulations 2008 No 1597 will be made available upon request to the governing authorities Compatible Power Drives When i...

Страница 24: ...AULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY AND OR ITS AFFILIATED ENTITIES IN THE UNITED STATES AND OR OTHER COUNTRIES 2021 VICTAULIC COMPANY ALL RIGHTS RESERVED OPERATING AND MAINTENANCE INS...

Отзывы: