background image

 

Operating and

Maintenance

Instructions

Manual

 

PFT505

 

Pressfit Tool

 

Failure to follow Instructions and warnings can result in serious personal injury.

• When using electric tools, basic safety precautions should always be followed

to reduce the risk of fire, electric shock and injury.

• Before installing, operating, or servicing the PFT505 tool read all instructions in

this Manual and all warning labels on the tool.

• Before setting up and operating the Victaulic Pressfit tool, read “Victaulic

Pressfit Product Assembly Instructions” (I-500).

• Always wear safety glasses and foot protection.

• Save this instruction manual.

If you need additional copies of the manual or instructions, or have any questions
about the safe operation of this tool, contact Victaulic Tool Company, P.O. Box 31,
Easton, PA 18044-0031, Phone: 610-559-3300.

FM

APPROVED

UL

®

LISTED

SA

APPROVED

 

R

 

TM-PFT505.1005 Rev.B  Page 1  Tuesday, May 29, 2001  6:01 PM

Содержание PFT505

Страница 1: ...tructions in this Manual and all warning labels on the tool Before setting up and operating the Victaulic Pressfit tool read Victaulic Pressfit Product Assembly Instructions I 500 Always wear safety glasses and foot protection Save this instruction manual If you need additional copies of the manual or instructions or have any questions about the safe operation of this tool contact Victaulic Tool C...

Страница 2: ...al injury or death if instructions including recommended precautions are not followed The use of the word CAUTION signifies possible hazards or unsafe practices which could result in personal injury product or property damage if instructions including precautions are not followed NOTICE The use of the word NOTICE signifies special instructions which are important but not related to hazards INDEX H...

Страница 3: ...ctions Be certain that all guards and tool parts are properly installed and secured 2 Keep work area clean Cluttered areas benches and slippery floors invite accidents 3 Keep alert Do not operate tool if ill or drowsy from medication or fatigue Avoid horseplay around tool and keep bystanders a safe distance from tool Don t operate tool when you are tired 4 Wear safety glasses and footwear 5 Wear p...

Страница 4: ...ly and replace if damaged Keep tool dry clean and free from oil and grease INTRODUCTION Victaulic Pressfit System products are designed for use only with UL ULC Listed and FM Approved Schedule 5 steel pipe or approved Victaulic stainless steel pipe Victaulic stainless steel pipe carries the label Victaulic Pressfit Pipe Certified For Use With Pressfit Products The Pressfit System requires a Pressf...

Страница 5: ...connected to permanent ground such as a properly grounded outlet box Refer to Tool Set Up page 3 EXTENSION CORD REQUIREMENTS Use only 3 wire extension cords that have 3 prong grounding type plugs and 3 pole receptacles that accept the tool s plug Replace or repair damaged cords To reduce the risk of electric shock check the electrical source for proper grounding and follow the instructions below C...

Страница 6: ...en marking pipe ends 11 97 0629 Rev A INSERTION DEPTH 1 inch inch 1 inch 1 inch 1 inch MINIMUM PIPE NIPPLE LENGTH REQUIRED 2 2 3 3 5 R008500LAB Before installing Pressfit products operating or servicing the Pressfit Tool read the Product Assembly and Tool Operation Manual and all warning labels on the tool and tool box Only connect tool to a grounded electrical source 20 amp maximum Always disconn...

Страница 7: ... Prefix Example PFY001 PFZ Prefix Example PFZ002 3DC Prefix Example 3DC007 2DC Prefix Example 2DC20001 Pressfit Jaws Size Jaw Model No PFJ 050 PFJ 075 1 PFJ100 1 PFJ125 1 PFJ150 2 PFJ200 TOOL SETUP PRESS JAW INSTALLATION AND REMOVAL PRESS JAW INSTALLATION A separate press jaw set is available for each pipe size 1 1 1 and 2 The proper size press jaw must be used for the size of fit ting being insta...

Страница 8: ...into an inter nally grounded electrical source 20 amps max imum 2 Pick up tool placing hands as shown The Pressfit tool is designed to be used ONLY with Victaulic Pressfit products and designated pipe Read the Victaulic Pressfit Product Assembly Instructions I 500 The proper size press jaw must be used for the size of fitting being installed Failure to follow instructions may result in personal in...

Страница 9: ... close the jaws and move hand back to support neck of tool 6 When the tool is properly positioned fully press the switch and hold it down until the pressing cycle is complete Check to be certain that the o ring pocket raised area of the Pressfit fitting is fully seated in the press jaw cavity and that the indent lugs are over the fitting Failure to fully seat press jaw cavity prior to pressing may...

Страница 10: ...nal injury or death CLEANING AND LUBRICATION Unplug Pressfit Tool and remove press jaws prior to all repair and maintenance work PRESS JAWS At frequent intervals remove the jaws from the tool and remove any dirt from the pressing sur faces using the small wire brush provided with tool After cleaning the jaws lubricate the bolts pins and sliding segment of the jaws with a commercial machine oil ROL...

Страница 11: ...ng properly Attempting to press pipe other than UL ULC Listed and FM Approved Schedule 5 steel pipe or approved Victaulic stainless steel pipe Extension cord too long or of wrong size Schedule 5 steel pipe harder than Rb70 Jaws dirty Check jaw size and replace with proper size See Accessories Check and ensure that O ring bead on fitting is centered in jaw cavity Use only UL ULC Listed and FM Appro...

Страница 12: ...to change product specifications designs and standard equipment without notice and without obligation Registered Trademark of Victaulic Company of America Copyright 1998 Victaulic Company of America Printed in U S A TM PFT505 1005 Rev B 3 98 TM PFT505 1005 Rev B Page 12 Tuesday May 29 2001 6 01 PM ...