Not for
Reproduction
31
If the battery is not removed from the machine, make sure that the key on the
control panel is in the “OFF” position. Connect the battery charger to the mains
power supply and then attach the connector (2):
-to the corresponding connector of the machine’s wiring (if fitted)
-or otherwise to the wire (3) with the serrated-edge grips, attaching
theses to the terminals of the battery in the following sequence:
1- first the red grip to the positive terminal (+)
2- and then the black grip to the negative terminal (-).
The battery charger LED lights (4-5-6) (see previous page) show the type of
functioning:
4- Green = Battery charger live
5- Yellow = Charging at 14.7 Volts
6- Yellow = Maintenance charge at 13.6 Volts
whether they are lit or off signals:
-normal condition:
-
particular condition:
-
normal charging of a partilly
discharged battery.
-
if, after a few
minutes it becomes...
-
for about
30 seconds
-
continuous
-
no power being
supplied or battery
charger faulty
-
the thermal
protection
device has
cut in.
-
the battery has already been
sufficiently charged before the
48 hours.
-
on being
connected
-
the battery is on
maintenance charge.
48 hours
after being
connected.
-
possible inversion of terminals in connecting the grips;
-the battery is in a deep discharge connection and is being slowly
regenerated. The true charging takes place when the LED (5)
lights up after a few hours.
-
the battery is insufficiently recharged in the 48 hours and requires a second
charging cycle by disconnecting and reconnecting after 5 seconds the battery
charger to the mains power supply. When another 24 hours have passed, if the
LED (5) does not go out it means that the battery is damaged beyond repair and
cannot take the recharge.
6. MAINTENANCE (cont.)