DC Inverter Duct Type Unit
31
Note:
When the unit is connected with the wired controller, the error code will be
simultaneously shown on it.
(2). Instructions to the Error Indicating Lamps on the Panel of the Duct Type
Unit.
Fig. 6.1
6.2 Working Temperature Range
Table 6.2
Test Condition
Indoor Side
Outdoor Side
DB(°C)
WB(°C)
DB(°C)
WB(°C)
Nominal Cooling
27
19
35
24
Nominal Heating
20
−
7
6
Rated Cooling
32
23
48
−
Low Temp. Cooling
21
15
-15
−
Rated Heating
27
−
24
18
Low Temp. Heating
20
−
-10
-11
Note:
①
. The design of this unit conforms to the requirements of ISO5151 standard.
②
. The air volume is measured at the relevant standard external static
pressure.
③
. Cooling (heating) capacity stated above is measured under nominal
working conditions corresponding to standard external static pressure. The
parameters are subject to change with the improvement of products, in
which case the values on nameplate shall prevail.