UG:119
Page 14
PFC MegaPAC-EL™ and PFC MegaPAC-HPEL™ Mechanical Drawing
14AWG WIRE
J10-9
J10-1O
J10-11
J10-12
VCC +5V, 0.3A
SIGNAL GROUND
AC POWER OK
GEN SHUTDOWN
J10 INTERFACE
J10-1
J10-2
J10-3
J10-4
J10-5
J10-6
J10-7
J10-8
E/D-1
E/D-2
E/D-3
E/D-4
E/D-5
E/D-6
E/D-7
E/D-8
INPUTS
DO NOT
WITHOUT EARTH GROUND
L2
115/230
V
AC
300V
DC
INPUT CONNECTIONS
J9-1 EARTH GROUND
J9-2 L2-NEUTRA
L
J9-3 L1
HOUSING-MOLEX P/N: 39-01-2120.
L1
47 – 500Hz
OPERATE
CLAMPING SCREWS
47 TO 500 Hz
300VDC
115/230 VAC
L2
INPUTS
L1
OPERATE
GROUND
EARTH
WITHOUT
DO NOT
MATING HDWR
:
TERMINALS-MOLEX P/N: 39-00-0039 CRIMP TOOL-MOLEX P/N: 11-01-0122
(T0P AND BOTH SIDES)
(RE-DESIGNED LENGTH)
(ORIGINAL LENGTH)
RE-DESIGNED STUD
AND PANEL
ORIGINAL STUD
AND PANEL
FAN
(DIRECTION OF AI
R
FLOW OPTIONAL
)
6.04 [153.42]
3.37 [85.60]
5.100 [129.54]
.470 [11.94]
.21 [5.33]
2.92 [74.17]
10.01 [254.25]
.21 [5.33]
2.92 [74.17]
.25 [6.35]
10.01 [254.25]
15.62 [396.81]
15.50 [393.63]
2.75 [69.85]
10.01 [254.25]
15.18 [385.69]
.53 [13.39]
.41 [10.35]
NOTE: SET SCREW MAXIMUM TORQUE = 4.4IN.LBS
TORQUE = 4.4 INCH POUNDS
NOTE: SET SCREW MAXIMUM
LABEL NO: 94-00046 REV
B
LABEL NO: 94-00046 REV B
3.28 [83.19]
1.40 [35.56]
2.77 [70.23]
.73 [18.52]
.47 [11.94]
1.46 [37.03]
[18.5mm]
5.10 [129.5mm]
7 SP. @ .7285
1/4 - 20 SERRATED FLANGED
NUT ZINC PLATED STEEL
WITH OPTIONAL BUSS BARS
CUSTOMER MOUNTING HOLES (16X) M4 OR #8-32 THREAD MAXIMUM
SCREW PENETRATION .150 [4.00mm]
FROM OUTSIDE SURFACE.
12
11
10
9
8
7
6
5
4
3
2
1
J10
RE-DESIGNED
ORIGINAL
NUT
FLANGED
INSERT
BRASS
STUD IS 1/8 INCH LONGER.
MAY BE PRESENT. THE NEW OUTPUT PANEL HAS A BRASS INSERT AND THE
NOTE: EITHER THE ORIGINAL OR RE-DESIGNED OUTPUT STUD AND PANEL COMBINATION
OUTPUT PANEL AND STUDS