XX123-00-02 Rev 203 Network Interface
Installation
••
5
f.
Program Status: Depending on the progress on the installation, various messages may appear:
You must connect – click Connect button
Ready to apply – click Apply button
Writing network setting – sending address information to unit
IP installation is completed. You must restart the server – power off and power on the unit
Waiting for server response – communication not established; close the IPInstaller application
and then restart procedure from step 6.
After the IP address is installed, click OK and reset the unit by disconnecting and reconnecting the power cord
to the AURC-NIU.
If the same IP address is being assigned to multiple NIUs concurrently, the IP address associated with the MAC
address of the previous NIU must be cleared from the ARP table before the next NIU can be assigned the IP
address. From the Command (DOS) window type in the following procedure.
Enter arp –d 100.122.1.222 (100.122.1.222 is an example IP address; enter the specific IP address
for the AURC-NIU).
Follow this procedure for each subsequent NIU requiring the same IP address.
Running the Ping Function
To confirm that the IP address is communicating, perform a Ping function. Equipment connections remain as
above.
1. Find the Command Prompt (MS-DOS Prompt) with the Start button. This opens a command window.
2. On the command line, type in “ping” after C:\WINDOW>, leave a space, and then type in the IP address,
putting periods between the numbers (i.e., C:\WINDOWS>ping 10.0.0.25).
3. If the AURC-NIU IP address is responding, a “Reply from…” message appears, confirming the connection
and the IP address assigned. See screen below. Note that after first initializing the IP address for the AURC-
NIU, it may indicate that there is “No Reply from…”, however a reply could take as long as 60 seconds
before it will echo back “Reply from…” This is a normal response.
Содержание XX123-00-02
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 6: ...ii Quick Installation XX123 00 02 Rev 203 Network Interface Connections for Operation Standalone...
Страница 7: ...XX123 00 02 Rev 203 Network Interface Quick Installation iii Network...
Страница 8: ......
Страница 19: ...XX123 00 02 Rev 203 Network Interface Operation 11...
Страница 26: ...18 Technical Information XX123 00 02 Rev 203 Network Interface...