background image

XX123-00-02 Rev 203 Network Interface 

Installation  

••

  5 

f. 

Program Status: Depending on the progress on the installation, various messages may appear: 
You must connect – click Connect button 
Ready to apply – click Apply button 
Writing network setting – sending address information to unit 
IP installation is completed. You must restart the server – power off and power on the unit 
Waiting for server response  – communication not established; close the IPInstaller application 
and then restart procedure from step 6. 

 
After the IP address is installed, click OK and reset the unit by disconnecting and reconnecting the power cord 
to the AURC-NIU. 
 
If the same IP address is being assigned to multiple NIUs concurrently, the IP address associated with the MAC 
address of the previous NIU must be cleared from the ARP table before the next NIU can be assigned the IP 
address. From the Command (DOS) window type in the following procedure. 

Enter arp –d 100.122.1.222 (100.122.1.222 is an example IP address; enter the specific IP address 
for the AURC-NIU). 

Follow this procedure for each subsequent NIU requiring the same IP address. 

Running the Ping Function 

To confirm that the IP address is communicating, perform a Ping function. Equipment connections remain as 
above. 

1.  Find the Command Prompt (MS-DOS Prompt) with the Start button. This opens a command window. 

2.  On  the command line, type in “ping” after C:\WINDOW>, leave a space, and then type in the IP address, 

putting periods between the numbers (i.e., C:\WINDOWS>ping 10.0.0.25). 

3.  If the AURC-NIU IP address is responding, a “Reply from…” message appears, confirming  the connection 

and the IP address assigned. See screen below. Note that after first initializing the IP address for the AURC-
NIU, it may indicate that there is “No Reply from…”, however a reply could take as long as 60 seconds 
before it will echo back “Reply from…” This is a normal response. 

 

 

 

Содержание XX123-00-02

Страница 1: ...oduct specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc Windows is a trademark of Microsoft Corp VICON INDUSTRIES INC 89 ARKAY DRIVE...

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ...XX123 00 02 Rev 203 Network Interface Quick Installation i Quick Installation Connections to Install the IPInstaller...

Страница 6: ...ii Quick Installation XX123 00 02 Rev 203 Network Interface Connections for Operation Standalone...

Страница 7: ...XX123 00 02 Rev 203 Network Interface Quick Installation iii Network...

Страница 8: ......

Страница 9: ...ion to take place Any dynamic IP address installed into the Interface will not provide access over a WAN In any case the specific video of any particular AurorAcorD will be displayed on the PC that is...

Страница 10: ...nterface for IP installation and also connects interface to AurorAcorD for operation ETHERNET RJ45 10Base T 100Base T network connector used for Wide Area Network WAN or Local Area Network LAN PRESET...

Страница 11: ...omplete the PC must be rebooted before proceeding IPInstaller Vicon DVR Applying the IPInstaller Before the AURC NIU is connected to the AurorAcorD the IP address of the AURC NIU must be set up 1 Conn...

Страница 12: ...so on up to 254 The Subnet Mask is the same as those of your PC When installing the AURC NIU on a corporate network ask your network administrator for a unique IP address Note For operation over a WAN...

Страница 13: ...assigned the IP address From the Command DOS window type in the following procedure Enter arp d 100 122 1 222 100 122 1 222 is an example IP address enter the specific IP address for the AURC NIU Foll...

Страница 14: ...on any CCTV monitor 4 Connect the supplied Remote Control Cable part number 1298 5244 01 to the SERIAL port of the AURC NIU and one of the AurorAcorD COM ports Use only the supplied cable Note Refer...

Страница 15: ...he PC monitor settings must be 1024 x 768 pixels minimum and color setting equivalent to 32 bit for screen image to display correctly Network Considerations The AurorAcorD Digital Recorder can be used...

Страница 16: ...ize of the video image displayed When set at 1024 the Full Image is 6 75 in width and 4 75 in in length and the Small Image is 3 75 in width and 2 75 in in length b Site List Displays a list of AURC N...

Страница 17: ...rage capacity e Record Setup File information for video and image setup A User define selection allows the addition of text before the date Long date time includes the full date and time Short date ti...

Страница 18: ...Space Displays disk space left on the PC When the PC is full recording to the hard drive of the PC stops Recording on the AurorAcorD is not affected A message appears when the PC is at full capacity...

Страница 19: ...XX123 00 02 Rev 203 Network Interface Operation 11...

Страница 20: ...etup to NTSC 640 x 240 normal Clears all the user accounts and passwords user reverts to admin and password reverts vicon It is important to note that a result of using the PRESET button is that the n...

Страница 21: ...in Europe contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Na...

Страница 22: ...istance The larger cable results in a lower DC resistance and better video quality with increased difficulty in handling and installation Let the required picture quality and cable distance provide a...

Страница 23: ...f cooling required for an installation Line Cord 12 VDC adapter cord supplied Radio Frequency Emission Rating FCC Class A COMPUTER REQUIREMENTS Hardware Minimum requirements for WindowsTM 2000 ME XP F...

Страница 24: ...on average user bandwidth requirements Total Number of System Users Limitless CONNECTORS AND INDICATORS Rear Panel Video Input BNC 1 channel Video Output BNC I channel auto termination Network Interfa...

Страница 25: ...ters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32 2 712 8781 Far...

Страница 26: ...18 Technical Information XX123 00 02 Rev 203 Network Interface...

Отзывы: