5
TWO-CHANNEL VIDEO RECEIVER
ELECTRICAL
Power Requirements:
13.5 - 16 VDC.
Current Requirement:
35 m A.
Power Consumption:
1.4 W.
Heat Equivalent:
0.08 btu/min (0.02 kg-cal/min).
Note: These figures represent the conversion of 100% of the elec-
trical energy to heat. Actual percentage of heat generated will be
less and will vary from product to product. These figures are pro-
vided as an aid in determining the extent of cooling required for an
installation.
Safety Standard:
UL 1950.
Radio Frequency
Emissions Rating:
FCC Class A.
European Community
(CE) Standards:
EN60950.
VIDEO
Number of Channels:
2.
Modulation Type:
Frequency Modulation (FM).
Formats Supported:
NTSC and PAL.
Full System Bandwidth:
8 MHz per channel.
Horizontal Video Resolution:
>640 TV lines.
Input/Output Impedance:
75 ohms.
Optimum Input Signal:
1 V p-p nominal composite video.
Output Signal Level:
1 V p-p nominal, composite video,
unity gain, ±5%.
Differential Phase:
1.7º.
Differential Gain:
1.6%.
Signal-to-Noise Ratio:
>50 dB (at max path loss).
Interconnection Distance:
Video devices to transmitter:
≤
100 ft (30 m).
Receiver to video devices:
≤
100 ft (30 m).
Note: RG59/U coaxial cable, Belden No. 9259 or equivalent, is
recommended for video interconnection.
OPTICAL
Maximum
Optical Attenuation:
13 dB.
Gain Control:
Fully automatic optical (OAGC).
Optical Wavelength:
850 nm.
Fiber Type:
62.5 um.
Operating Distance:
3.2 mi (5.2 km).
Note: Operating distance is approximate and will be affected by
the type and number of splices in the fiber and by the exact type
of fiber used.
CONNECTORS AND INDICATORS
Optical Connector:
Two ST type.
Video Connector:
Two BNC.
Power Connector:
Made via card cage rack.
Level/Loss™:
Two Bicolor LEDs.
MECHANICAL
R
ACK
-
MOUNT
C
ARDS
Module Width:
1 slot, 1.0 in. (25.4 mm).
Weight:
0.61 lb (0.28 kg).
Shipping Dimensions:
Length: 9.75 in. (247.7 mm).
Width:
5.25 in. (133.4 mm).
Height: 1.0 in. (25.4 mm).
Shipping Volume:
0.03 cu ft (0.00085 cu m).
Shipping Weight:
0.80 lb (0.36 kg).
Finish:
Black semigloss paint.
ENVIRONMENTAL
Operating Temperature Range: -40 to 167° F (-40 to 75° C).
Operating Humidity Range:
0 to 95% relative,
noncondensing.
TECHNICAL INFORMATION