Vicon V662-D Скачать руководство пользователя страница 21

Vicon Standard Equipment Warranty 

 

Vicon Industries Inc. (the “Company”) warrants your equipment to be free from defects in material and 
workmanship under Normal Use from the date of original retail purchase for a period of three years, with the 
following exceptions: 
 

1.  VCRs, all models: Labor and video heads warranted for 120 days from date of original retail 

purchase. All other parts warranted for one year from date of original retail purchase. 

2.  LCD and CRT monitors, all models: One year from date of original retail purchase. 
3.  Uninterruptible Power Supplies: Two years from date of original retail purchase. 
4.  VDR-700 Recorder Series: One year from date of original retail purchase. 
5.  V5616MUX: One year from date of original retail purchase. 
6.  Arecont Cameras: One year from date of original retail purchase. 
7.  FMC series fiber-optic media converters and associated accessories: Lifetime warranty. 
8.  For PTZ cameras, “Normal Use” excludes prolonged use of lens and pan-and-tilt motors, gear 

heads, and gears due to continuous use of “autopan” or “tour” modes of operation. Such 
continuous operation is outside the scope of this warranty. 

9.  Vicon Security Management Systems (SMS) All Models: All hardware is warranted for two years 

from date of original retail purchase. 

10.  Any product sold as “special” or not listed in Vicon’s commercial price list: One year from date of 

original retail purchase. 

 

Date of retail purchase is the date original end-user takes possession of the equipment, or, at the sole 
discretion of the Company, the date the equipment first becomes operational by the original end-user. 
 
The sole remedy under this Warranty is that defective equipment be repaired or (at the Company’s option) 
replaced, at Company repair centers, provided the equipment has been authorized for return by the 
Company, and the return shipment is prepaid in accordance with policy. 
 
The Company will not be obligated to repair or replace equipment showing abuse or damage, or to parts 
which in the judgment of the Company are not defective, or any equipment which may have been tampered 
with, altered, misused, or been subject to unauthorized repair. 
 

Software supplied either separately or in hardware is furnished on an “As Is” basis. Vicon does not 
warrant that such software shall be error (bug) free. Software support via telephone, if provided at 
no cost, may be discontinued at any time without notice at Vicon’s sole discretion. Vicon reserves 
the right to make changes to its software in any of its products at any time and without notice. 

 

This Warranty is in lieu of all other conditions and warranties express or implied as to the Goods, 
including any warranty of merchantability or fitness and the remedy specified in this Warranty is in 
lieu of all other remedies available to the Purchaser. 

 
No one is authorized to assume any liability on behalf of the Company, or impose any obligations on it in 
connection with the sale of any Goods, other than that which is specified above. In no event will the 
Company be liable for indirect, special, incidental, consequential, or other damages, whether arising from 
interrupted equipment operation, loss of data, replacement of equipment or software, costs or repairs 
undertaken by the Purchaser, or other causes. 
 
This warranty applies to all sales made by the Company or its dealers and shall be governed by the laws of 
New York State without regard to its conflict of laws principles. This Warranty shall be enforceable against 
the Company only in the courts located in the State of New York.  
 
The form of this Warranty is effective March 1, 2011.  

 
THE TERMS OF THIS WARRANTY APPLY ONLY TO SALES MADE WHILE THIS WARRANTY IS IN 
EFFECT. THIS WARRANTY SHALL BE OF NO EFFECT IF AT THE TIME OF SALE A DIFFERENT 
WARRANTY IS POSTED ON THE COMPANY’S WEBSITE, 

WWW.VICON-SECURITY.COM

. IN THAT 

EVENT, THE TERMS OF THE POSTED WARRANTY SHALL APPLY EXCLUSIVELY. 
 
 
 
 
 
 
 

Vicon Part Number: 8006-9010-03-09   Rev 0311 

Содержание V662-D

Страница 1: ...ly as described in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Vicon Industries Inc 89 Arkay Drive Hauppauge New York 11788 Tel 631 952 2288 Fax 631 951 2288 Toll Free 800 645 9116 24 Hour Technical Support 800 34 VICON 800 348 4266 UK 44 0 1489 566300 Document Number 8009 8232 00 02 Product specifications subject...

Страница 2: ...olid object fall into the cabinet unplug the unit and have it checked by qualified personnel before operating it any further Unplug the unit from the wall outlet if it is not going to be used for several days or more To disconnect the cord pull it out by the plug Never pull the cord itself Allow adequate air circulation to prevent internal heat build up Do not place the unit on soft surfaces rugs ...

Страница 3: ...MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE CAUTION CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT THIS CLASS A DI...

Страница 4: ...tacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unu...

Страница 5: ...es from the carton and verify that they were not damaged in shipment The content of the package includes 1 Color CCD camera 2 Mini DIN connector for video or dc type auto iris lens 3 CS adapter ring for C mounting C lenses TABLE OF CONTENTS INTRODUCTION 6 CAMERA OVERVIEW 7 BACK FOCUS ADJUSTMENT 8 THE DEFINITION OF TERMS 9 CAMERA ADJUSTMENT 11 CONTROL AND CONNECTIONS DAY NIGHT I O TERMINALS 18 LENS...

Страница 6: ...ange Detection z Various Alarm Method Period Snooze Polarity Select z Frame Control Auto 1 7 sec z Privacy Mask or Mosaic MAX 15 area 4 point polygonal transparency z Digital PTZ z White Pixel Remove z Back Light Compensation z Digital Effect H V reverse 180 degree rotate inverse freeze z System Lock 4 Digit password z Auto Electronic Shutter 1 50 1 100 000 and manual electronic shutter modes 1 50...

Страница 7: ...Enter Button q Right Button r Down Button s Day Night External I O Motion ALARM OUT RS 485 UTP optional t Power Indicator u Video Output Connector BNC v UTP or BNC Transformation Switch optional w AC DC Compatible Input Terminal AC Power Cord REAR VIEW n r REAR VIEW Free Voltage o p u v t q s 7 ...

Страница 8: ...lens to the camera body and plug in the auto iris connector 2 Place a neutral density filter in front of the lens This will force the lens iris to open to the max In the case of a manual lens open the lens iris to its maximum 3 Set the focus of the lens to full infinity 4 Set the zoom to Wide 5 Aim the camera at a high contrast object a distance away and move the back focus lever to bring object i...

Страница 9: ...ects with a large amount of background light that would make it practically impossible to see any details of the subjects Adjusts the iris so that a distinctive subject and the background are delivered at the same time Wide Dynamic Range WDR Extends the action of BLC When both high brightness subjects and low brightness subjects are in the same scene overexposure in the high brightness subjects or...

Страница 10: ...he original giving the appearance of being zoomed in Widen the intervals between the pixels in the original signal according to the magnification and then filing these intervals with interpolation signals Communication Allows for the connection to external devices such as keyboards through the menu interface Iris Control Automatically adjusts the level of the iris according to changing light level...

Страница 11: ... FLC Flicker less Flicker less On Off 3 AGC Auto Gain Control AGC Gain Off Low Middle High 4 Sens Up Slow Shutter Maximum Slow Shutter select x2 x32 and Off 5 Offset Add Force the picture to turn up at low luminance environment BLC WDR 1 Normal AE BLC WDR function off 2 WDR Wide Dynamic Range Wide dynamic range mode on 3 EHLC Excessive High Light Compensation EHLC mode on excessive lighting compen...

Страница 12: ...n with D PTZ function that On Off When the motion triggered in the area zoom and move to the area with D PTZ Motion Trace Motion trace mode on Tracks an object through a scene and generates an alarm Face Trace Face Trace mode on Tracks face through a scene and generate an alarm Sens Down lower value is more widen the scope to judge face 0 127 Min Size Minimum face size configuration 0 minimum face...

Страница 13: ...unting accuracy Expand or decrease the detection zone area to compensate for this Multiple objects passing through the detection zone will affect accuracy Entrance Entrance counting mode The object move in through the entrance counting number increases Size Press Enter button adjust the size of the Entrance zone Posi Press Enter button adjust the Position of the Entrance zone Alarm Cnt Set alarm o...

Страница 14: ...ress the Enter button to access the Pan Tilt Use the Left and Right buttons adjust to digital pan Use the Up and Down buttons adjust to digital tilt Press the Enter button to exit PT Reset Pan Tilt Reset Press the Enter button to reset digital pan and tilt 4 Freeze Select the still mode on off 5 Frame Control Select term of refresh rate for output video This function is useful to reduce the record...

Страница 15: ...r with OSD Key and Press Enter to input the character Comm RS 485 Communication Press the Enter button to access the Comm Cam ID Select the camera ID 001 255 Baud Rate Select serial communication speed 2400 4800 9600 19200 Protocol RS 485 protocol COMMAND FASTRAX PELCO D PELCO P Title Edit camera title Title Site_0 ൯ ENT Del Clear Cancel Accept ABCDEFGHIJKLM NOPQRSTUVWXYZ a b c d e f g h i j k l m...

Страница 16: ...0 100 Only activates when AC power is applied 5 White Pixel Det Exe Press Enter button to turn White Pixel Compensation mode Start ENT to Adj Press Enter button to start White Pixel Compensation start Proc Process to find white pixel Done Process ended Det Count Result of white pixel detection Func Select erasing white pixel function On Off using the Left and Right buttons Det Level Select the jud...

Страница 17: ...I Main Manu menu in bottom lines A Exit Save Exit B Load Load Default Value II Sub Menu menu in bottom lines A Return Return to previous menu B Exit Save Exit 1 Exit Menu Save Exit Current environment values save Exit Disappear menu osd 2 Load Default Setup Yes Load default to current configuration and return to previous menu No No operation and return to previous menu 17 ...

Страница 18: ... LED OFF DAY 4 DAY NIGHT OUTPUT 5 COM DAY NIGHT EXTERNAL INPUT 3pin Used to connect an external light sensor to the camera to provide an on off signal when Day Night mode is set to External Open contact DAY Close contact NIGHT 3 DAY NIGHT INPUT 5 COM 3 ALARM OUT 6pin TTL level Motion detection signals are output through this port Active state is configurable 4 POWER INPUT TERMINAL This terminal ac...

Страница 19: ...mage quality might be poor It is recommended to use a high quality lens to improve the image quality under low illumination INSTALLING AUTO IRIS LENS 1 Remove the cover from the iris lens plug supplied and solder the lens cable to the plug as shown below DC type Pin 1 Damping Pin 2 Damping Pin 3 Drive Pin 4 Drive Iris Control Cable Automatic Iris Lens Heat Connector Cover Shrinkable Tubes Connecto...

Страница 20: ...am ID Title DNR 2DNR 3D NR Gain Adjust DNR Demo Day Night Auto Day Night Ext Video Analytics Zone Motion trace Face trace Minefield Absent Cross Entrance Scene Change Detection Privacy zone Max 15 Tilt Color Transparency Mosaic Effect V Flip Mirror Rotation Nega Posi Freeze Sharpness Sense up x32 Sharpness 0 15 steps Cam ID 001 255 WDR WDR x512 Level Adjust D Zoom x256 D Zoom D PTZ Support Bad Pix...

Страница 21: ...h policy The Company will not be obligated to repair or replace equipment showing abuse or damage or to parts which in the judgment of the Company are not defective or any equipment which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hardware is furnished on an As Is basis Vicon does not warrant that such software shall...

Страница 22: ...e Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Vicon Germany Kornstieg 3 D 24537 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 97 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon security com ...

Отзывы: