Low luminance, object color and object size can affect accuracy.
¾
Cross : Cross counting mode
Zone : Select Cross Zone using the Left and Right buttons (Zone 1, Zone
2).
Size : Adjust the size of the Cross zone.
Posi : Adjust the position of the Cross zone.
Direction : Select Cross Direction.
Alarm Cnt : Set alarm out cross count. Alarm count number is delaying
number before output alarm.
Reset Cnt : Cross count reset.
Fast moving objects will affect counting.
Expand or decrease the detection zone area to compensate for this.
Long objects will affect counting accuracy.
Expand or decrease the detection zone area to compensate for this.
Multiple objects passing through the detection zone will affect accuracy.
¾
Entrance : Entrance counting mode. The object move in through the entrance,
counting number increases
Size : Press Enter button adjust the size of the Entrance zone.
Posi : Press Enter button adjust the Position of the Entrance zone.
Alarm Cnt : Set alarm out entrance count. Alarm count number is
delaying number before output alarm.
Reset Cnt : Entrance count reset.
2)
Sens Down
: Adjust to Motion Sensitivity using left/right Buttons
Crossing objects are ignored. Multiple objects will not be detected.
If the distance is increases between the camera and entrance, the result may be
inaccurate.
13