REC Out Trigger Operation Mode
To use the trigger operation mode,
TRIG OUT
must be set to
LOW
and
REC MODE
must be set to
TIME
LAPSE
. This setting does not recognize Video Loss as an alarm condition.
When an alarm occurs, this signals the VCR to record.
Trigger connection on rear panel of V5900MUX:
Alarm In / Out
Pin No. Signal Pin No. Signal
1 Not Used 14 Alarm 3 in
2 Not Used 15 Alarm 2 in
3 Not Used 16 Alarm 1 in
4 Not Used 17 NO
5 Not Used 18 COM
6 Not Used 19 NC
7 Not Used 20 GND
8 Alarm 9 in 21 GND
9 Alarm 8 in 22 GND
10 Alarm 7 in 23 GND
11 Alarm 6 in 24 GND
12 Alarm 5 in 25 GND
13 Alarm 4 in
Trig In/Out
Pin No. Signal
1 Trigger In (VEXT)
2 GND
3 Trig Out (TTL to VCR to VCR alarm input)
7.1 Computer Remote Control
The V5900MUX uses a very simple command set, each command consisting of three characters. The first
character in all cases is the slash or virgule(/). The unit looks only for a three-character command, with an initial
slash. It ignores all other characters. If a mistake is made in entering a command, just type in another slash
character followed by the appropriate character for the desired command. The commands are listed in the Table
2, RS-232 Commands.
Signal Format is as follows:
1. Data Format: 1,200 Baud (Selectable)/8 Data Bit/No Parity/One Stop Bit.
2. Mode: Half Duplex Mode (Not Echo Received Character).
RS-232 Pinout
Pin 1 Not Used
Pin 2 RS-232 In
Pin 3-4 Not Used
Pin 5 GND
Pin 6 – 9 Not Used