*P-ON: Power On
*C”N” V/L: Channel “N” Video Loss ( ex. C9 V/L : Ch.9 Video Loss)
*ALM RS: Alarm Reset
*C”N” ALM: Channel “N” Alarm (ex. C4 ALM : Ch.4 Alarm)
*PGM: Programming
*A-CLR: All Clear
*F-SET: Factory Setting
5.9 System Setup
z
Select
SYSTEM SETUP
on the
MAIN MENU
. The following menu is displayed:
SYSTEM SETUP
(1) COMMUNICATION
SETUP
(2) PASSWORD
SETUP
5.9.1 Communication Setup
z
z
z
z
Select
COMMUNICATION SETUP
on the
SYSTEM SETUP
menu and press
ENTER
key to choose the
communication speed. The options of
BAUD RATE
are:
1200 bps, 2400 bps, 4800 bps, 9600 bps, 19600 bps, 38400 bps
COMMUNICATION SETUP
BAUD RATE : 1200BPS
UNIT ADDRESS : 00
COMMUNICATION: RS-232
Select
UNIT ADDRESS
to designate the address of the unit by pressing
(+)
or
(-)
key.
The addresses available are from 00 ~ 99 (only for RS-485).
Select
COMMUNICATION
to choose the communication method. The options are:
RS-232
RS-485
(not available)
5.9.2 Password Setup
Select
PASSWORD SETUP
and then press
(+)
or
(-)
key to toggle the options :
DISABLE, ENABLE
13
PASSWORD SETUP
PASSWORD : DISABLE
NEW PASSWORD: _ _ _ _