15
Computer Remote Control
V5400Mux uses a very simple command set, each command consisting of three characters. The first character
in all cases is the slash or virgule(/). The unit looks only for a three-character command, with an initial slash. It
ignores all other characters. If a mistake is made in entering a command, just type in another slash character
followed by the appropriate character for the desired command. The commands are listed in the Table-RS -232
Commands.
Signal format is as follows:
1. Data Format : 1,200 Baud / 8 Data Bit / No Parity / One Stop Bit
2. Mode : Half Duplex Mode(Not Echo Received Character)
RS232 pinout
Pin 1 : Not used
Pin 2 : Receive
Pin 3-4: Not used
Pin 5 : Common
Pin 6 – 9: Not used
Table RS-232 Commands
COMMAND RS-232 CODE
Title /TI
VCR input /VR
Rec View /RV
Alarm /AM
Menu /MU
Zoom /ZO
PIP /PI
FRZ /FR
Down /DN
Left /LF
Right /RG
SEQ /SG
Enter /ET
Numeric 01 /01
Numeric 02 /02
Numeric 03 /03
Numeric 04 /04
7.
Maintenance
The V5400MUX Multiplexer requires no routine maintenance and is designed for long, trouble-free use under
normal operating conditions. Repair should only be attempted by qualified personnel.