2
•
Configuration & Installation
XX074 Rev 101 Variable-Speed Keypad
Standalone
In a standalone system, there is no control system (CPU). You may connect receivers and domes directly to
the keypad in this configuration. The 4-wire half-duplex RS-422 protocol for the V1411X-DVC is driven in a
multi-drop, tri-state manner that allows you to connect directly to Surveyor2000 domes, which use RS-485,
without the need for a converter box.
UP TO 255 RECEIVER/DOMES
V1411X-DVC
POWER SUPPLY
(Refer to Technical
Information for details)
RJ45-to-RJ45 CABLE
110 VAC or
230 VAC
RJ-45
TERMINATION
BOX
Recommended Data Cable
Belden 8723 8000 ft (2400 m)
Belden 8162 15,000 ft (4600 m)
Belden 9729 15,000 ft (4600 m)
Belden 9182 25,000 ft (7600 m)
COM. OUT +
12 VDC or
9 VAC AC
INPUT
RESP. IN +
COM. OUT –
NOT USED
GROUND
RESP. IN –
The V1411X-DVC is shipped with the appropriate power supply for your installation. For 230 VAC, a 9 VAC
power supply is included. A 12 VDC power supply is included for 120 VAC. For illustration purposes, the power
supply shown is a desktop version (the 12 VDC power supply actually plugs directly into the wall outlet). The
two leads from the power supply will be connected to the RJ-45 termination box. You may connect the two
leads to either of the termination box screws shown below - polarity is not a factor for either the DC or the AC
supply.