background image

6  

  Operation

XX074 Rev 101 Variable-Speed Keypad

Operation

Operating Modes

Accessing Operating Modes

5

0

...

Press the appropriate
number key.

Press & Hold

PROG

Release

PROG

Mode

Description

Normal operating mode
Preset Store mode.
Set Dwell mode.
Setup mode.

1
2
3
4

Alarms

Acknowledging Alarms

Viewing Alarm Video

For control systems with an independent stack 
mode, press ALARM again after all alarms are 
cleared from the currently-selected alarm 
monitor. This will select the next alarm monitor 
if it has active alarms. Continue with the alarm 
acknowledgment procedure to clear alarms.

To view but not acknowledge 
alarms, press CANCEL or SEQ 
to step through active alarms. 

SEQ will step you through the 
alarms from the first active 
alarm to the last active alarm. 

CANCEL will step you through 
the alarms from the first active 
alarm to the last active alarm. 

If ALARM flashes in the display 
window, press ALARM to view 
the alarm video. (If alarms are 
sequencing, the first press of 
the ALARM key will stop the 
sequencing.)

If  ALARM continues 
to flash in the display 
window, press 
ALARM until all 
alarms are cleared.

Press 
ALARM to 
clear the 
alarm.

Notes: If the currently-selected monitor is not defined as an alarm monitor, press ALARM before performing the procedure below in 
order to select the lowest numbered alarm monitor. Monitors are defined as alarm monitors as discussed in the programming 
manual for your control system.

ALARM

CANCEL

SEQ

OR

Auxiliary Function Control

Controlling Auxiliary Functions

Which auxiliary functions are momentary 
and which are latching depends upon 
your receiver. Refer to your receiver 
documentation if necessary.

Momentary functions 
stay active as long as 
the number key is 
pressed.

To activate latching 
auxiliary functions, 
press an AUX key 
and release.

9

1

...

Press

Enter aux number

AUX

Communication Failure

Press

CANCEL

If the com fail is on a 
camera that is NOT 
currently selected, 
COMFL and a block 
caret will flash.

This selects the 
camera having 
the com fail.

Press

CANCEL

This acknowledges 
the failure.

If the com fail is on 
a camera that IS 
currently selected, 
COMFL flashes.

Press

CANCEL

This acknowledges 
the failure.

Mode 1 is automatically entered
after power is applied or if the
keypad is reset. Refer to
Indicators in Display in the
Technical Information chapter for
LCD status messages.

Содержание V1411X-DVC

Страница 1: ...07 WEB www vicon cctv com Vicon Industries Inc does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error free or perform...

Страница 2: ...rmined by turning equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with re...

Страница 3: ......

Страница 4: ...6 Operating Modes 6 Alarms 6 Auxiliary Function Control 6 Communication Failure 6 Crosspoint Reset 7 Lens Operation 7 Presets 7 Manual Switching 7 Salvos and Tours V1400 control systems only 7 Sequen...

Страница 5: ...only fits into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the s...

Страница 6: ...411X DVC Variable Speed Keypad operates as a standalone controller for dome receivers without the need for matrix switchers or in a multi keypad installation using a NOVA control system Compatible wit...

Страница 7: ...ERMINATION BOX Recommended Data Cable Belden 8723 8000 ft 2400 m Belden 8162 15 000 ft 4600 m Belden 9729 15 000 ft 4600 m Belden 9182 25 000 ft 7600 m COM OUT 12 VDC or 9 VACAC INPUT RESP IN COM OUT...

Страница 8: ...bution Line Control VICON V1400X IDL POWER CPU 10 9 8 7 6 5 4 3 2 1 STATION VICON A U X V1422 RJ 45 TERMINATION BOX RESP OUT COM IN RESP OUT NOT USED GROUND COM IN V1411X DVC V1411X DVC V1411X DVC Up...

Страница 9: ...ess for this keypad use this setting for Standalone mode 1 64 for NOVA mode Baud Rate Sets the communication baud rate All keypads in your NOVA system must have the same baud rate 1200 2400 4800 9600...

Страница 10: ...aving a choice during setup operating mode 4 Beeps four times for Active alarm s On Off Key Click Audible indicator for key presses Keypad Sounder must be ON On Off Preset 1 ON Alarm Recalls preset 1...

Страница 11: ...press ALARM until all alarms are cleared Press ALARM to clear the alarm Notes If the currently selected monitor is not defined as an alarm monitor press ALARM before performing the procedure below in...

Страница 12: ...PROG Release PRESET Press PRESET Press 2 Press This stores a preset for the currently selected camera 9 0 Enter preset number Manual Switching 9 MON 0 Selecting a Monitor Press MON Press Enter monito...

Страница 13: ...o normal operating mode 9 9 9 9 Deleting All Cameras Press Press SEQ Press 2 Press Hold Perform these steps if you are not already in Mode 2 PROG Release PROG Using the Joystick Setting Pan and Tilt S...

Страница 14: ...or Key For monitor selection enabling Cancel Key Used to clear data entries Sequencing Key Starts camera sequencing Programming Key Used to change operating mode Preset Key Recalls or stores preset po...

Страница 15: ...Europe contact Vicon Industries U K Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a N...

Страница 16: ...urope Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 322 712 8780 Fax 322 7...

Отзывы: