Vicon V1410X-DVC Скачать руководство пользователя страница 18

XX074-02-01 Rev 703 Variable-Speed Keypad 

Shipping Instructions  

  13 

Mechanical 

 
V1411X-DVC and V1411X-DVC-230: 
Construction:   

Zinc plated steel. 

Finish: 

  Black 

“walnut”. 

Dimensions:  

 

Height: 2.25 in. (57 mm). 
Width: 11.5 in. (292 mm). 
Depth: 6.9 in. (175 mm). 

Weight:  

 

3.0 lb (1.4 kg). 

 
V1411J-DVC and V1411J-DVC-230: 
Construction:   

Zinc plated steel. 

Finish: 

  Black 

“walnut”. 

Dimensions:  

 

Height: 3.0 in. (75 mm). 
Width: 11.5 in. (292 mm). 
Depth:  6.9 in. (175 mm). 

Weight:  

 

3.0 lb (1.4 kg). 

 

Shipping Instructions 

 
Use the following procedure when returning a unit to the factory: 
 

1.  Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name 

of the Vicon employee who issued the R.A. 

 

Vicon Industries Inc. 
89 Arkay Drive 
Hauppauge, NY  11788 
Phone: 631-952-CCTV (2288); Toll-Free: 1-800-645-9116; Fax: 631-951-CCTV (2288) 

 

For service or returns from countries in Europe, contact: 

 

Vicon Industries Ltd 
Brunel Way 
Fareham, PO15 5TX 
United Kingdom 
Phone:  +44 (0) 1489 566300; Fax: +44 (0) 1489 566322 

 

2.  Attach a sheet of paper to the unit with the following information: 
 

a.  Name and address of the company returning the unit 

b.  Name of the Vicon employee who issued the R.A. 

c.  R. A. number 

d.  Brief description of the installation 

e.  Complete description of the problem and circumstances under which it occurs 

f. 

Unit’s original date of purchase, if still under warranty 

 

3.  Pack the unit carefully. Use the original shipping carton or its equivalent for maximum protection. 

4.  Mark the R.A. number on the outside of the carton on the shipping label. 

V1410X-DVC and V1410X-DVC-230: 
Construction:  Zinc plated steel. 
Finish:  

Black “walnut”. 

Dimensions:  

Height: 2.0 in. (50 mm). 
Width: 6.5 in. (164 mm). 
Depth: 7.0 in. (180 mm). 

Weight:  

2.1 lb (0.9 kg). 

 
Environmental

 

 
Operating Temperature: 32 - 122° F (0-50° C). 
Operating Humidity: Up to 90 % relative, 

noncondensing. 

Содержание V1410X-DVC

Страница 1: ...800 287 1207 WEB www vicon cctv com Vicon Industries Inc does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error free...

Страница 2: ......

Страница 3: ......

Страница 4: ...Passcode Setup 5 Keypad Setup 6 Operation 8 Operating Modes 8 Alarms 8 Auxiliary Function Control 8 Communication Failure 9 Crosspoint Reset 9 Lens Operation 9 Presets 9 Manual Switching 10 Salvos and...

Страница 5: ......

Страница 6: ...EN61000 3 3 1995 and Immunity EN50130 4 1995 and A1 1998 The keypad operates as a standalone controller for dome receivers without the need for matrix switchers or in a multi keypad installation using...

Страница 7: ...a 9 VAC power supply is included The two leads will be connected to the RJ 45 termination box You may connect the two leads to either of the termination box screws shown in the figures to follow polar...

Страница 8: ...box screws shown below polarity is not a factor for either the DC or the AC supply 110 VAC or 230 VAC NOVA Control System Distribution Line Control VICON V1400X IDL POWER CPU 10 9 8 7 6 5 4 3 2 1 STA...

Страница 9: ...ct all like signals for example connect Command In on the first keypad s RJ 45 box to Command In on the second keypad s termination box and so forth V1411X DVC V1411X DVC RJ45 to RJ45 CABLE 110 VAC or...

Страница 10: ...e 2 New Passcode 5 Passcodes 2 11 are for users Enter the 4 digit passcode for the first user press A P to save the passcode and continue to set up passcodes if needed Note that you do not have to use...

Страница 11: ...address each keypad must have a unique address After you have set up the keypad completely power your control system and refer to its documentation to set the Keypad State to Auto in the control syst...

Страница 12: ...Off Key Click Audible indicator for key presses On Off Preset 1 On Alarm Recalls preset 1 home on the receiver in an alarm state Standalone mode only On Off Alarm Slf Clr Alarm Self Clear Automatical...

Страница 13: ...ss CANCEL or SEQ to step through active alarms SEQ will step you through the alarms from the first active alarm to the last active alarm CANCEL will step you through the alarms from the first active a...

Страница 14: ...ized A P Controlling the Lens Zoom Focus Iris Lens Speed Toggle key to automatically adjust to ambient lighting conditions or deactivate Note that autoiris operation has priority over manual iris cont...

Страница 15: ...Tour Enter tour number Press SEQ at any time to run the quick access tour Press Cancelling a Running Tour or Salvo Press Use the joystick to move to a new position CANCEL Sequential Switching Note Seq...

Страница 16: ...VC Only Twist clockwise for Zoom In Twist counterclockwise for Zoom Out Setting Autopan Speed Control Note This procedure is for Surveyor series domes only using 1300 speed control type Note For recei...

Страница 17: ...umerical Keypad Camera monitor selection dwell time input mode selection etc Camera Key Assigns selected camera to selected monitor Monitor Key For monitor selection enabling Cancel Key Used to clear...

Страница 18: ...V 2288 For service or returns from countries in Europe contact Vicon Industries Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to...

Страница 19: ...Europe Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32...

Отзывы: