background image

Disassembly 

The SurveyorVFT Fixed Camera Dome can be easily disassembled by removing the camera mechanism 
from the housing or enclosure. A safety cord is always available to safely hang the camera mechanism while 
assembling or disassembling.  

In-Ceiling Installation 

1.  Gently pull down on the lower dome’s outside edge, with two hands, until all molded tabs snap out of 

Pendant Installation 

.  Push in the tabs on the housing until the camera mechanism is released. 

place. 

2.  Push in the tabs to release the camera mechanism from the enclosure. It will hang from the safety cord. 

3.  If it is necessary to completely remove the camera mechanism, disconnect the safety cord clip and all 

cables. 

1.  On outdoor version only, loosen the four (4) trim ring screws from the outdoor lower dome. 

2.  Gently pull down on the lower dome’s outside edge, with two hands, until all molded tabs snap out of 

place. 

3

4.  Allow the SurveyorVFT to gently drop down until it is supported by the safety cord. 

5.  If it is necessary to completely remove the SurveyorVFT, remove all cable connections and disconnect 

the clip on the end of the safety cord from the tab on the enclosure. 

 
 

XX152-01-00 Rev 404 SurveyorVFT Fixed Camera Dome 

Installation  

  17 

Содержание SurveyorVFT SVFT-C266A

Страница 1: ...al situations and must not be used for this purpose Copyright 2004 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and its logo are registered tr...

Страница 2: ......

Страница 3: ...ent off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Re...

Страница 4: ...asive or aerosol cleaners d The product does not operate per the operating instructions Perform Vicon recommended adjustments modifications and troubleshooting only to avoid unit damage and personal i...

Страница 5: ...g 4 Mounting from Above the Ceiling 5 Optional Independent Support 6 Indoor Pendant 7 Outdoor Pendant 8 Cable Connections 8 Coaxial Video Cable 8 Camera Power Connections 9 DIP Switch Settings 10 Came...

Страница 6: ...Quick Installation In Ceiling No Access to Ceiling ii Quick Installation XX152 01 00 Rev 404 SurveyorVFT Fixed Camera Dome...

Страница 7: ...In Ceiling Access to Ceiling XX152 01 00 Rev 404 SurveyorVFT Fixed Camera Dome Quick Installation iii...

Страница 8: ...Pendant Indoor iv Quick Installation XX152 01 00 Rev 404 SurveyorVFT Fixed Camera Dome...

Страница 9: ...Pendant Outdoor XX152 01 00 Rev 404 SurveyorVFT Fixed Camera Dome Quick Installation v...

Страница 10: ......

Страница 11: ...axial video transmission NTSC PAL SVFT C266A SVFT C266A C 8726 8726 01 In ceiling 1 3 in ExView high resolution color camera with isolated power input and 2 6 6 mm autoiris varifocal lens 24 VAC smoke...

Страница 12: ...signs the note on all copies of the bill If the agent does not have claim forms contact the carrier s office Inspection for Concealed Damage As soon as possible after delivery unpack the unit and insp...

Страница 13: ...provided for temperature control Shroud The shroud is a 5 4 in 137 mm textured black ABS plastic shell It has a 1 4 in 35 6 mm slotted opening for the camera This shroud conceals the position of the...

Страница 14: ...m Refer to Figure 1 3 Measure and make a small mark at position B 8 2 in 208 mm placing the scribe as perpendicular to the A edge as possible 4 Place the scribe across B and C Rotate the scribe around...

Страница 15: ...ting from Above the Ceiling Use this method of installation if the space above The ceiling material must provide suitable strength to support the weight of the SurveyorVFT fixed dome with the two flip...

Страница 16: ...strain relief fitting Tighten the two 2 strain relief fitting screws to compress the cables Do not overtighten the screws and crush the cables 4 If cables are channeled through flexible cable a Route...

Страница 17: ...amera mechanism s tab Allow the SurveyorVFT mechanism to hang from the housing Refer to Figure 2 7 Route each cable from the inside top its mating connector on the camera PC ounts on a Vicon mount or...

Страница 18: ...er turn 6 Verify that each cable drops from the pipe opening at least 15 in 381 mm in length 7 Lift the SurveyorVFT camera mechanism up to the housing sunshield and attach the housing s safety cord cl...

Страница 19: ...8 Refer Powe to Figure 4 Refer to Table 2 for the input power connections 2 25 mm of insulation off power cables Then strip off approximately 0 25 in prevent incorrect 1 Find the detachable power cabl...

Страница 20: ...8 for the location and setting of the switches To obtain the sharpest picture possible the iris stment shou the internal AGC of the camera is not operational The day night camera includes a switch to...

Страница 21: ...Setting D Number s 1 Iris DC AES DC Iris ON Automatic Electronic Shutter OFF 2 Flickerless FL ON OFF Shutter speed set to be fixed at 1 100 sec Normal position 3 Backlight Compensation ON OFF Set when...

Страница 22: ...Potentiometer DIP Switch Location 2 6 6 mm Lens Version Figure 7 Figure 8 DIP Switch Settings 2 6 6 mm Lens Version 12 Installation XX152 01 00 Rev 404 SurveyorVFT Fixed Camera Dome...

Страница 23: ...the two nuts if nec frame use an open end 11 32 wrench Position the camera and retighten nuts On units with the 2 6 6 mm lens the camera mounting bracket position can to the dome by loosening the lock...

Страница 24: ...it snaps into place on both 11 enclosure Lift the lower dome up to the SurveyorVFT and align the molded tabs on the lower recesses on the inner enclosure Press the lower dome into the SurveyorVFT sid...

Страница 25: ...ve to the closeness to the dome by loosening the lock nuts changing the vertical position of the camera mounting frame within the slots in The lens can be manually adjusted for iris focus and angle of...

Страница 26: ...ary on either side of the camera mounting frame use an open end 11 32 wrench Position the camera and retighten nuts On units with the 2 6 6 mm lens the camera mounting bracket position can be adjusted...

Страница 27: ...amera mechanism from the enclosure It will hang from the safety cord 3 If it is necessary to completely remove the camera mechanism disconnect the safety cord clip and all cables 1 On outdoor version...

Страница 28: ...y s alcohol and water using a microwave safe aluminum free paper towel Dry with clean dry pressurized air 4 Scratches or surface blemishes on the exterior or interior may be remove a soft nonabrasive...

Страница 29: ...for maximum protection 4 Mark the R A number on the outside of the carton on the shipping label Use the following procedure when returning a unit to the factory 1 Call or write Vicon for a Return Auth...

Страница 30: ...Types T No Type No Type No Type Conductor Type Shield and Coverage DC Resistance ohms per 1000 feet km rials only cable with a p r conductor because these r conductor with low DC resistance is require...

Страница 31: ...e 3 OPERATIONAL Tilt and Horizontal Adju 3 axis ustment 360 til tated is 360 ECHANICAL Application Indoor and outdoor models Mounting In ceiling and pendant models ELECTRICAL Input Voltage 24 VAC Indo...

Страница 32: ...g re ange 40 to 150 F 40 to 65 C torage Humidity Up to 90 relative noncondensing ind Load Outdoor heavy rain or snow driven by winds up to 80 mph Height 10 Dome Diamete Outdoor Pendant Total Diameter...

Страница 33: ...olor 46 0 19 I Line lock switch ctable 60 20 1 PA d AG AG 0 d 50 dB B C o C o B SVFT P266M SVFT P266M C 1 3 CCD 2 1 interlace NTSC PAL Color 48 019 0 I Line lock switch ctable 0 10 0 ff ff 48 48 SVFT...

Страница 34: ...ris 106 78 2 35 8 P266 2 6 6 varifocal 47 6 S P550 anual iris 2 4 3 2 2 SV SV FT W266DNA FT W266DNA C 2 6 6 varifocal with autoiris 106 78 2 35 8 47 6 2 S W266 i 6 47 6 78 8 SV S FT W550A VFT W550A C...

Страница 35: ...ive or any ent which may have been tampered with altered misused or been subject to unauthorized repair So r w rnished on an As Is basis Vicon does not warrant that su oftw l o b e a upport via teleph...

Страница 36: ...pe Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32 2 71...

Отзывы: